Midterm and one-year outcome of amphilimus polymer free drug eluting stent in patients needing short dual antiplatelet therapy. Insight from the ASTUTE registry (AmphilimuS iTalian mUlticenTer rEgistry). (15th March 2017)
- Record Type:
- Journal Article
- Title:
- Midterm and one-year outcome of amphilimus polymer free drug eluting stent in patients needing short dual antiplatelet therapy. Insight from the ASTUTE registry (AmphilimuS iTalian mUlticenTer rEgistry). (15th March 2017)
- Main Title:
- Midterm and one-year outcome of amphilimus polymer free drug eluting stent in patients needing short dual antiplatelet therapy. Insight from the ASTUTE registry (AmphilimuS iTalian mUlticenTer rEgistry)
- Authors:
- Godino, Cosmo
Chiarito, Mauro
Donahue, Michael
Testa, Luca
Colantonio, Riccardo
Cappelletti, Alberto
Monello, Alberto
Magni, Valeria
Milazzo, Diego
Parisi, Rosario
Nicolino, Annamaria
Moshiri, Shahram
Fattori, Rossella
Aprigliano, Gianfranco
Palloshi, Altin
Caramanno, Giuseppe
Montorfano, Matteo
Bedogni, Francesco
Briguori, Carlo
Margonato, Alberto
Colombo, Antonio - Abstract:
- Abstract: Background: To assess clinical outcomes of patients needing short dual antiplatelet therapy (S-DAPT) after PCI with Cre8 polymer-free amphilimus eluting-stent (AES). The Cre8-AES with pure i-Carbofilm coating was supposed to induce faster stent endothelialization and reduce device thrombogenicity. Methods: We performed a sub-analysis of unrestricted consecutive patients treated with Cre8-AES between August 2011 and January 2015. Two groups were formed: 1) patients discharged with S-DAPT (≤ 3-month), because of high bleeding risk or attending urgent non-cardiac surgery; and 2) patients discharged with Recommended DAPT duration (R-DAPT; ≥ 6-month). The primary ischemic- and bleeding-safety endpoints were Target Vessel Failure (TVF, composite endpoint of cardiac-death, target vessel-myocardial infarction and target vessel-revascularization), and major-bleeding (BARC ≥ type-3a) at 6-month and 1-year. Results: 106 patients (8.7%) were discharged with ≤ 3-month DAPT (83 ± 19 days; S-DAPT group) and 1102 patients (90.6%) with ≥ 6-month DAPT (342 ± 62 days; R-DAPT group). Between S-DAPT and R-DAPT groups no significant differences were observed in TVF at 1-year (5.7% vs 5.1%); 1-year BARC major bleeding rate was higher in S-DAPT group (3.4% vs 0.2%, p = 0.007) with all bleeding events occurred within 3 months. The landmark analysis (started at 90 days, ended at 1 year) showed no differences in BARC major bleedings between groups (0% vs. 0.3%). Conclusions: The results ofAbstract: Background: To assess clinical outcomes of patients needing short dual antiplatelet therapy (S-DAPT) after PCI with Cre8 polymer-free amphilimus eluting-stent (AES). The Cre8-AES with pure i-Carbofilm coating was supposed to induce faster stent endothelialization and reduce device thrombogenicity. Methods: We performed a sub-analysis of unrestricted consecutive patients treated with Cre8-AES between August 2011 and January 2015. Two groups were formed: 1) patients discharged with S-DAPT (≤ 3-month), because of high bleeding risk or attending urgent non-cardiac surgery; and 2) patients discharged with Recommended DAPT duration (R-DAPT; ≥ 6-month). The primary ischemic- and bleeding-safety endpoints were Target Vessel Failure (TVF, composite endpoint of cardiac-death, target vessel-myocardial infarction and target vessel-revascularization), and major-bleeding (BARC ≥ type-3a) at 6-month and 1-year. Results: 106 patients (8.7%) were discharged with ≤ 3-month DAPT (83 ± 19 days; S-DAPT group) and 1102 patients (90.6%) with ≥ 6-month DAPT (342 ± 62 days; R-DAPT group). Between S-DAPT and R-DAPT groups no significant differences were observed in TVF at 1-year (5.7% vs 5.1%); 1-year BARC major bleeding rate was higher in S-DAPT group (3.4% vs 0.2%, p = 0.007) with all bleeding events occurred within 3 months. The landmark analysis (started at 90 days, ended at 1 year) showed no differences in BARC major bleedings between groups (0% vs. 0.3%). Conclusions: The results of this multicenter registry show that the use of Cre8 AES in patients needing short DAPT (≤ 3-month) was safe regarding ischemic events and could favor a reduction of bleeding events related to the recommended DAPT. A large randomized trial is necessary to support these preliminary findings. … (more)
- Is Part Of:
- International journal of cardiology. Volume 231(2017)
- Journal:
- International journal of cardiology
- Issue:
- Volume 231(2017)
- Issue Display:
- Volume 231, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 231
- Issue:
- 2017
- Issue Sort Value:
- 2017-0231-2017-0000
- Page Start:
- 54
- Page End:
- 60
- Publication Date:
- 2017-03-15
- Subjects:
- Stent thrombosis -- Bleeding risk -- Dual antiplatelet therapy -- Amphilimus eluting stent
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2017.01.023 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 291.xml