Assessment of coronary calcification using calibrated mass score with two different multidetector computed tomography scanners in the Copenhagen General Population Study. Issue 88 (March 2017)
- Record Type:
- Journal Article
- Title:
- Assessment of coronary calcification using calibrated mass score with two different multidetector computed tomography scanners in the Copenhagen General Population Study. Issue 88 (March 2017)
- Main Title:
- Assessment of coronary calcification using calibrated mass score with two different multidetector computed tomography scanners in the Copenhagen General Population Study
- Authors:
- Fuchs, Andreas
Groen, Jaap M.
Arnold, Ben A.
Nikolovski, Sasho
Knudsen, Andreas D.
Kühl, J. Tobias
Nordestgaard, Børge G.
Greuter, Marcel J.W.
Kofoed, Klaus F. - Abstract:
- Abstract: Objective: Population studies have shown coronary calcium score to improve risk stratification in subjects suspected for cardiovascular disease. The aim of this work was to assess the validity of multidetector computed tomography (MDCT) for measurement of calibrated mass scores (MS) in a phantom study, and to investigate inter-scanner variability for MS and Agaston score (AS) recorded in a population study on two different high-end MDCT scanners. Materials and methods: A calcium phantom was scanned by a first (A) and second (B) generation 320-MDCT. MS was measured for each calcium deposit from repeated measurements in each scanner and compared to known physical phantom mass. Random samples of human subjects from the Copenhagen General Population Study were scanned with scanner A (N = 254) and scanner B (N = 253) where MS and AS distributions of these two groups were compared. Results: The mean total MS of the phantom was 32.9 ± 0.8 mg and 33.1 ± 0.9 mg (p = 0.43) assessed by scanner A and B respectively – the physical calcium mass was 34.0 mg. Correlation between measured MS and physical calcium mass was R 2 = 0.99 in both scanners. In the population study the median total MS was 16.8 mg (interquartile range (IQR): 3.5–81.1) and 15.8 mg (IQR: 3.8–63.4) in scanner A and B (p = 0.88). The corresponding median total AS were 92 (IQR: 23–471) and 89 (IQR: 40–384) (p = 0.64). Conclusion: Calibrated calcium mass score may be assessed with very high accuracy in a calciumAbstract: Objective: Population studies have shown coronary calcium score to improve risk stratification in subjects suspected for cardiovascular disease. The aim of this work was to assess the validity of multidetector computed tomography (MDCT) for measurement of calibrated mass scores (MS) in a phantom study, and to investigate inter-scanner variability for MS and Agaston score (AS) recorded in a population study on two different high-end MDCT scanners. Materials and methods: A calcium phantom was scanned by a first (A) and second (B) generation 320-MDCT. MS was measured for each calcium deposit from repeated measurements in each scanner and compared to known physical phantom mass. Random samples of human subjects from the Copenhagen General Population Study were scanned with scanner A (N = 254) and scanner B (N = 253) where MS and AS distributions of these two groups were compared. Results: The mean total MS of the phantom was 32.9 ± 0.8 mg and 33.1 ± 0.9 mg (p = 0.43) assessed by scanner A and B respectively – the physical calcium mass was 34.0 mg. Correlation between measured MS and physical calcium mass was R 2 = 0.99 in both scanners. In the population study the median total MS was 16.8 mg (interquartile range (IQR): 3.5–81.1) and 15.8 mg (IQR: 3.8–63.4) in scanner A and B (p = 0.88). The corresponding median total AS were 92 (IQR: 23–471) and 89 (IQR: 40–384) (p = 0.64). Conclusion: Calibrated calcium mass score may be assessed with very high accuracy in a calcium phantom by different generations of 320-MDCT scanners. In population studies, it appears acceptable to pool calcium scores acquired on different 320-MDCT scanners. … (more)
- Is Part Of:
- European journal of radiology. Issue 88(2017)
- Journal:
- European journal of radiology
- Issue:
- Issue 88(2017)
- Issue Display:
- Volume 88, Issue 88 (2017)
- Year:
- 2017
- Volume:
- 88
- Issue:
- 88
- Issue Sort Value:
- 2017-0088-0088-0000
- Page Start:
- 21
- Page End:
- 25
- Publication Date:
- 2017-03
- Subjects:
- ASA gatston score -- CT computed tomography -- CGPS copenhagen general population study -- FBP filtered back protection -- MDCT multidetector computed tomography -- MS mass score
Agatston -- Calcium -- Multidetector computed tomography -- MDCT -- Mass score -- Population
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2016.12.033 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1525.xml