Single source dual energy CT: What is the optimal monochromatic energy level for the analysis of the lung parenchyma?. Issue 88 (March 2017)
- Record Type:
- Journal Article
- Title:
- Single source dual energy CT: What is the optimal monochromatic energy level for the analysis of the lung parenchyma?. Issue 88 (March 2017)
- Main Title:
- Single source dual energy CT: What is the optimal monochromatic energy level for the analysis of the lung parenchyma?
- Authors:
- Ohana, M.
Labani, A.
Severac, F.
Jeung, M.Y.
Gaertner, S.
Caspar, T.
Roy, C. - Abstract:
- Graphical abstract: Highlights: Lung parenchyma aspect varies with the monochromatic energy level in spectral CT. Optimal diagnostic and image quality is obtained at 50–55 keV. Mediastinum and parenchyma could be read on the same monochromatic energy level. Abstract: Objective: To determine the optimal monochromatic energy level for lung parenchyma analysis in spectral CT. Methods: All 50 examinations (58% men, 64.8 ± 16yo) from an IRB-approved prospective study on single-source dual energy chest CT were retrospectively included and analyzed. Monochromatic images in lung window reconstructed every 5 keV from 40 to 140 keV were independently assessed by two chest radiologists. Based on the overall image quality and the depiction/conspicuity of parenchymal lesions, each reader had to designate for every patient the keV level providing the best diagnostic and image quality. Results: 72% of the examinations exhibited parenchymal lesions. Reader 1 picked the 55 keV monochromatic reconstruction in 52% of cases, 50 in 30% and 60 in 18%. Reader 2 chose 50 keV in 52% cases, 55 in 40%, 60 in 6% and 40 in 2%. The 50 and 55 keV levels were chosen by at least one reader in 64% and 76% of all patients, respectively. Merging 50 and 55 keV into one category results in an optimal setting selected by reader 1 in 82% of patients and by reader 2 in 92%, with a 74% concomitant agreement. Conclusion: The best image quality for lung parenchyma in spectral CT is obtained with the 50–55 keVGraphical abstract: Highlights: Lung parenchyma aspect varies with the monochromatic energy level in spectral CT. Optimal diagnostic and image quality is obtained at 50–55 keV. Mediastinum and parenchyma could be read on the same monochromatic energy level. Abstract: Objective: To determine the optimal monochromatic energy level for lung parenchyma analysis in spectral CT. Methods: All 50 examinations (58% men, 64.8 ± 16yo) from an IRB-approved prospective study on single-source dual energy chest CT were retrospectively included and analyzed. Monochromatic images in lung window reconstructed every 5 keV from 40 to 140 keV were independently assessed by two chest radiologists. Based on the overall image quality and the depiction/conspicuity of parenchymal lesions, each reader had to designate for every patient the keV level providing the best diagnostic and image quality. Results: 72% of the examinations exhibited parenchymal lesions. Reader 1 picked the 55 keV monochromatic reconstruction in 52% of cases, 50 in 30% and 60 in 18%. Reader 2 chose 50 keV in 52% cases, 55 in 40%, 60 in 6% and 40 in 2%. The 50 and 55 keV levels were chosen by at least one reader in 64% and 76% of all patients, respectively. Merging 50 and 55 keV into one category results in an optimal setting selected by reader 1 in 82% of patients and by reader 2 in 92%, with a 74% concomitant agreement. Conclusion: The best image quality for lung parenchyma in spectral CT is obtained with the 50–55 keV monochromatic reconstructions. … (more)
- Is Part Of:
- European journal of radiology. Issue 88(2017)
- Journal:
- European journal of radiology
- Issue:
- Issue 88(2017)
- Issue Display:
- Volume 88, Issue 88 (2017)
- Year:
- 2017
- Volume:
- 88
- Issue:
- 88
- Issue Sort Value:
- 2017-0088-0088-0000
- Page Start:
- 163
- Page End:
- 170
- Publication Date:
- 2017-03
- Subjects:
- BMI Body Mass Index -- CTA computed tomography angiography -- CTPA computed tomography pulmonary angiography -- DECT dual energy CT -- DLP Dose Length Product -- GFR glomerular filtration rate -- HU Hounsfield Unit -- ROI region of interest -- SE single energy -- SNR signal to noise ratio
Multidetector computed tomography -- Lung imaging -- Lung parenchyma -- Dual energy CT -- Biomedical technology assessment
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2017.01.016 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1525.xml