Evaluation of sclerosis in Modic changes of the spine using susceptibility-weighted magnetic resonance imaging. Issue 88 (March 2017)
- Record Type:
- Journal Article
- Title:
- Evaluation of sclerosis in Modic changes of the spine using susceptibility-weighted magnetic resonance imaging. Issue 88 (March 2017)
- Main Title:
- Evaluation of sclerosis in Modic changes of the spine using susceptibility-weighted magnetic resonance imaging
- Authors:
- Böker, Sarah M.
Bender, Yvonne Y.
Adams, Lisa C.
Fallenberg, Eva M.
Wagner, Moritz
Hamm, Bernd
Makowski, Marcus R. - Abstract:
- Highlights: SWMR allows a reliable detection of sclerosis in Modic changes. SWI has a better accuracy for detection of sclerosis in Modic changes than T1/T2w MR. By applying SWMR the use of additional CT/radiography can be minimized. Abstract: Purpose: To evaluate the diagnostic performance of susceptibility-weighted magnetic resonance imaging (SWMR) for the differentiation of sclerotic and non-sclerotic Modic changes (MC) of the spine compared to computed tomography (CT) and radiographs. Materials and methods: The Institutional Ethics-Review-Board approved this prospective study in advance. Written consent was obtained from all subjects. SWMR and standard T1/T2 MR of the cervical (n = 21) and/or lumbar spine (n = 34) were performed in 54 patients. 21 patients served as control. 18 patients were evaluated with CT; in all other patients radiographs were available. 67 Modic changes were identified on T1/T2 MR. On SWMR changes were classified as sclerotic and non-sclerotic based on signal intensity measurements. The sensitivity and specificity of SWMR and T1/T2 MR for differentiating between sclerotic and non-sclerotic Modic changes were determined with CT and radiographs as reference standard. Results: On SWMR, signal measurements between sclerotic and non-sclerotic Modic changes differed significantly (p < 0.01). On T1- and T2-weighted MR no significant difference (p > 0.05) was measured. On SWMR, a reliable differentiation between sclerotic and non-sclerotic Modic changesHighlights: SWMR allows a reliable detection of sclerosis in Modic changes. SWI has a better accuracy for detection of sclerosis in Modic changes than T1/T2w MR. By applying SWMR the use of additional CT/radiography can be minimized. Abstract: Purpose: To evaluate the diagnostic performance of susceptibility-weighted magnetic resonance imaging (SWMR) for the differentiation of sclerotic and non-sclerotic Modic changes (MC) of the spine compared to computed tomography (CT) and radiographs. Materials and methods: The Institutional Ethics-Review-Board approved this prospective study in advance. Written consent was obtained from all subjects. SWMR and standard T1/T2 MR of the cervical (n = 21) and/or lumbar spine (n = 34) were performed in 54 patients. 21 patients served as control. 18 patients were evaluated with CT; in all other patients radiographs were available. 67 Modic changes were identified on T1/T2 MR. On SWMR changes were classified as sclerotic and non-sclerotic based on signal intensity measurements. The sensitivity and specificity of SWMR and T1/T2 MR for differentiating between sclerotic and non-sclerotic Modic changes were determined with CT and radiographs as reference standard. Results: On SWMR, signal measurements between sclerotic and non-sclerotic Modic changes differed significantly (p < 0.01). On T1- and T2-weighted MR no significant difference (p > 0.05) was measured. On SWMR, a reliable differentiation between sclerotic and non-sclerotic Modic changes could be achieved, with a sensitivity of 100% and specificity of 95%. In contrast, the combination of T1-/T2-weighted MR yielded a significantly lower sensitivity to detect sclerosis (20%). Conclusion: SWMR allows a reliable detection of sclerosis in Modic changes with a higher accuracy compared to standard spine MR sequences, using radiographs and CT as reference standard. … (more)
- Is Part Of:
- European journal of radiology. Issue 88(2017)
- Journal:
- European journal of radiology
- Issue:
- Issue 88(2017)
- Issue Display:
- Volume 88, Issue 88 (2017)
- Year:
- 2017
- Volume:
- 88
- Issue:
- 88
- Issue Sort Value:
- 2017-0088-0088-0000
- Page Start:
- 148
- Page End:
- 154
- Publication Date:
- 2017-03
- Subjects:
- MRI magnetic resonance imaging -- MC Modic change -- CT computed tomography -- GRE gradient echo -- SWMR susceptibility-weighted magnetic resonance imaging -- TSE turbo spin echo -- TE time to echo -- TR time to repeat -- MEDIC multi-echo data imaging combination -- VB vertebral body -- ROC receiver operating characteristics -- CI confidence interval
Modic changes -- Susceptibility-weighted magnetic resonance imaging -- MRI -- Spine
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2016.12.024 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1525.xml