Fabrication of a highly sensitive electrochemiluminescence chlorpromazine sensor using a Ru(bpy)32+ incorporated carbon quantum dot–gelatin composite film. Issue 6 (1st February 2017)
- Record Type:
- Journal Article
- Title:
- Fabrication of a highly sensitive electrochemiluminescence chlorpromazine sensor using a Ru(bpy)32+ incorporated carbon quantum dot–gelatin composite film. Issue 6 (1st February 2017)
- Main Title:
- Fabrication of a highly sensitive electrochemiluminescence chlorpromazine sensor using a Ru(bpy)32+ incorporated carbon quantum dot–gelatin composite film
- Authors:
- Liu, Zhimin
Zhang, Fang
Cui, Lin
Wang, Kang
Zhan, Haijun - Abstract:
- Abstract : A novel electrochemiluminescence sensing platform for the sensitive detection of chlorpromazine (CPZ) was fabricated based on a Ru(bpy)3 2+ /carbon quantum dots/gelatin composite film. Abstract : A novel electrochemiluminescence sensing platform for the sensitive detection of chlorpromazine (CPZ) was fabricated based on a Ru(bpy)3 2+ /carbon quantum dots/gelatin composite film. Carbon quantum dots (CQDs) in the composite film which have the ability to enhance the ECL intensity were synthesized by a simple and cost-saving method. As Ru(bpy)3 2+ was entrapped in the gelatin (Gel), the efficient immobilization of Ru(bpy)3 2+ could be achieved, which resulted in a stable ECL signal. In addition, the ECL signal on the Ru(bpy)3 2+ /CQDs/Gel composite modified electrode was greatly amplified by CPZ. The electrochemical and ECL behaviors of the proposed sensor were investigated. Under the optimum conditions, the ECL intensity was well-proportional to the logarithm of CPZ concentration in the range of 5.0 × 10 −10 to 1.0 × 10 −5 M, with the detection limit as low as 8.0 × 10 −11 M (S/N = 3). Furthermore, the ECL sensor was successfully applied for the determination of CPZ in spiked urine samples and exhibited a desirable result, which indicated that this sensor has potential application in CPZ analysis in real samples.
- Is Part Of:
- Analytical methods. Volume 9:Issue 6(2017)
- Journal:
- Analytical methods
- Issue:
- Volume 9:Issue 6(2017)
- Issue Display:
- Volume 9, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 9
- Issue:
- 6
- Issue Sort Value:
- 2017-0009-0006-0000
- Page Start:
- 1011
- Page End:
- 1017
- Publication Date:
- 2017-02-01
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c6ay03369e ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 488.xml