McGrath Series 5 videolaryngoscope vs Airtraq DL videolaryngoscope for double-lumen tube intubation: A randomized trial. Issue 51 (December 2016)
- Record Type:
- Journal Article
- Title:
- McGrath Series 5 videolaryngoscope vs Airtraq DL videolaryngoscope for double-lumen tube intubation: A randomized trial. Issue 51 (December 2016)
- Main Title:
- McGrath Series 5 videolaryngoscope vs Airtraq DL videolaryngoscope for double-lumen tube intubation
- Authors:
- Wan, Li
Liao, Mingfeng
Li, Li
Qian, Wei
Hu, Rong
Chen, Kun
Zhang, Chuanhan
Yao, Wenlong - Other Names:
- Hanaoka. Kazuo section editor.
- Abstract:
- Abstract: Background: Many studies have shown Airtraq videolaryngoscope provided faster tracheal intubation and a higher success rate than other videolaryngoscopes. Recently, different types of videolaryngoscopes have been reported for use in double-lumen tube (DLT) intubation. However, the advantages and disadvantages between them remain undetermined for DLT intubation. In this study, we compared the Airtraq DL videolaryngoscope with the McGrath Series 5 videolaryngoscope for DLT intubation by experienced anesthesiologists. Methods: Ninety patients with expected normal airways were randomly allocated to either the Airtraq or McGrath group. The primary outcome was DLT intubation time. The secondary outcomes were glottic view, success rate, subjective ease of intubation (100-mm visual analog scale, 0 = easy; 100 = difficult), incidence of DLT malposition, and postoperative intubation-related complication. Results: The airway characteristics were comparable between the 2 groups. Cormack and Lehane grades significantly improved with the use of the McGrath and Airtraq videolaryngoscopes, compared with the Macintosh laryngoscope. The intubation success rate on the first attempt was 93% in the Airtraq group and 95% in the McGrath group ( P > 0.05). The intubation time in the McGrath group is longer than that in the Airtraq group (39.9 [9.1]s vs 28.6 [13.6]s, P < 0.05). But intubation difficulty score, the incidence of DLT malposition and intubation-related complication wereAbstract: Background: Many studies have shown Airtraq videolaryngoscope provided faster tracheal intubation and a higher success rate than other videolaryngoscopes. Recently, different types of videolaryngoscopes have been reported for use in double-lumen tube (DLT) intubation. However, the advantages and disadvantages between them remain undetermined for DLT intubation. In this study, we compared the Airtraq DL videolaryngoscope with the McGrath Series 5 videolaryngoscope for DLT intubation by experienced anesthesiologists. Methods: Ninety patients with expected normal airways were randomly allocated to either the Airtraq or McGrath group. The primary outcome was DLT intubation time. The secondary outcomes were glottic view, success rate, subjective ease of intubation (100-mm visual analog scale, 0 = easy; 100 = difficult), incidence of DLT malposition, and postoperative intubation-related complication. Results: The airway characteristics were comparable between the 2 groups. Cormack and Lehane grades significantly improved with the use of the McGrath and Airtraq videolaryngoscopes, compared with the Macintosh laryngoscope. The intubation success rate on the first attempt was 93% in the Airtraq group and 95% in the McGrath group ( P > 0.05). The intubation time in the McGrath group is longer than that in the Airtraq group (39.9 [9.1]s vs 28.6 [13.6]s, P < 0.05). But intubation difficulty score, the incidence of DLT malposition and intubation-related complication were comparable between groups ( P > 0.05). Conclusions: When using videolaryngoscopes for DLT intubation, the Airtraq DL is superior to the McGrath Series 5 in intubation time, but it does not decrease intubation difficulty. … (more)
- Is Part Of:
- Medicine. Volume 95:Issue 51(2016)
- Journal:
- Medicine
- Issue:
- Volume 95:Issue 51(2016)
- Issue Display:
- Volume 95, Issue 51 (2016)
- Year:
- 2016
- Volume:
- 95
- Issue:
- 51
- Issue Sort Value:
- 2016-0095-0051-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-12
- Subjects:
- double-lumen tube -- intubation -- thoracic anesthesia -- videolaryngoscope
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000005739 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 22.xml