Experience and complications associated with use of guide extension catheters in percutaneous coronary intervention. Issue 7 (23rd December 2015)
- Record Type:
- Journal Article
- Title:
- Experience and complications associated with use of guide extension catheters in percutaneous coronary intervention. Issue 7 (23rd December 2015)
- Main Title:
- Experience and complications associated with use of guide extension catheters in percutaneous coronary intervention
- Authors:
- Waterbury, Thomas M.
Sorajja, Paul
Bell, Malcolm R.
Lennon, Ryan J.
Mathew, Verghese
Singh, Mandeep
Sandhu, Gurpreet S.
Gulati, Rajiv - Abstract:
- Abstract : Objectives: To investigate the utility and safety of the GuideLiner "mother‐and‐child" catheter system during transradial and transfemoral percutaneous coronary intervention (PCI). Background: In patients with complex coronary anatomy, stent delivery can be challenging and result in procedural failure and complications. The GuideLiner is a coaxial guide extension system designed to enable deep vessel engagement and facilitate device delivery. The purpose of this study was to evaluate procedural success and safety in a series of GuideLiner‐facilitated PCI. Methods: Single center retrospective study of PCI utilizing the GuideLiner catheter between February 2010 and October 2014. Patients who underwent PCI without GuideLiner use during the same time period were used as controls for comparison. Results: A total of 363 cases of GuideLiner‐facilitated PCI were identified from 6, 088 unique PCI procedures performed during this same time period. Patients in the GuideLiner group were older (mean age 71.5 vs. 67.8, P < 0.001) and had more multivessel disease (72% vs. 63%, P = 0.001) compared with controls. Type C lesions were present in 78% of GuideLiner cases. Procedural success resulting in successful device delivery with the GuideLiner catheter was 80.2%. Stent deformation associated with GuideLiner use occurred in 2.2% (8/363), with the incidence of this complication decreasing over device iterations. Coronary dissection attributed to GuideLiner occurred in 3.3%Abstract : Objectives: To investigate the utility and safety of the GuideLiner "mother‐and‐child" catheter system during transradial and transfemoral percutaneous coronary intervention (PCI). Background: In patients with complex coronary anatomy, stent delivery can be challenging and result in procedural failure and complications. The GuideLiner is a coaxial guide extension system designed to enable deep vessel engagement and facilitate device delivery. The purpose of this study was to evaluate procedural success and safety in a series of GuideLiner‐facilitated PCI. Methods: Single center retrospective study of PCI utilizing the GuideLiner catheter between February 2010 and October 2014. Patients who underwent PCI without GuideLiner use during the same time period were used as controls for comparison. Results: A total of 363 cases of GuideLiner‐facilitated PCI were identified from 6, 088 unique PCI procedures performed during this same time period. Patients in the GuideLiner group were older (mean age 71.5 vs. 67.8, P < 0.001) and had more multivessel disease (72% vs. 63%, P = 0.001) compared with controls. Type C lesions were present in 78% of GuideLiner cases. Procedural success resulting in successful device delivery with the GuideLiner catheter was 80.2%. Stent deformation associated with GuideLiner use occurred in 2.2% (8/363), with the incidence of this complication decreasing over device iterations. Coronary dissection attributed to GuideLiner occurred in 3.3% (12/363) and became less frequent over the study period. Conclusions: In this consecutive series of GuideLiner supported PCI, the guide extension system enabled procedural success in the majority. A decline in device‐associated complications over time may be attributed to operator learning curve, patient selection, and improvement in catheter design. © 2015 Wiley Periodicals, Inc. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 88:Issue 7(2016)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 88:Issue 7(2016)
- Issue Display:
- Volume 88, Issue 7 (2016)
- Year:
- 2016
- Volume:
- 88
- Issue:
- 7
- Issue Sort Value:
- 2016-0088-0007-0000
- Page Start:
- 1057
- Page End:
- 1065
- Publication Date:
- 2015-12-23
- Subjects:
- PCI complications -- interventional devices -- complex PCI
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.26329 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1472.xml