Temporal Trends in Strut‐Level Optical Coherence Tomography Evaluation of Coronary Stent Coverage: A Systematic Review and Meta‐Analysis. Issue 7 (28th December 2015)
- Record Type:
- Journal Article
- Title:
- Temporal Trends in Strut‐Level Optical Coherence Tomography Evaluation of Coronary Stent Coverage: A Systematic Review and Meta‐Analysis. Issue 7 (28th December 2015)
- Main Title:
- Temporal Trends in Strut‐Level Optical Coherence Tomography Evaluation of Coronary Stent Coverage
- Authors:
- Lee, Kwan S.
Lee, Justin Z.
Hsu, Chiu‐Hsieh
Husnain, Muhammad
Riaz, Haris
Riaz, Irbaz Bin
Thai, Hoang
Cassese, Salvatore
Finn, Aloke
Samady, Habib
Byrne, Robert A. - Abstract:
- Abstract : Objectives: We sought to pool data from all studies with reported strut‐level data in human subjects evaluated by optical coherence tomography (OCT) surveillance and to compare the aggregate data of stent strut coverage on a longitudinal temporal timeline from initial implantation for different coronary stent subtypes. Background: Delayed strut coverage following drug‐eluting stent (DES) implantation is an important contributor to late stent thrombosis (LST). OCT can detect stent strut coverage. Methods: We conducted a systematic search of published or presented studies reporting OCT stent strut coverage of bare‐metal stents (BMS) and DES in PubMed, Embase, Web of Science, and the Cochrane Central Register of Controlled Trials to June 2014. Data from 3, 515 patients with strut‐level data on 731, 761 struts were analyzed. Results: The temporal kinetics of strut coverage differed according to stent type. The rate of strut coverage, reflected by the calculated regression coefficient, was found to be the highest in BMS, followed by early generation zotarolimus‐eluting stent, everolimus‐eluting stent, newer‐generation zotarolimus‐eluting stent, paclitaxel‐eluting stent, and sirolimus‐eluting stent ( p < 0.0001). Conclusions: Aggregate rates of stent strut coverage assessed by OCT surveillance differed according to stent type. The clinical implications of these differences require further study but may underlie the differences in rates of stent thrombosis observed inAbstract : Objectives: We sought to pool data from all studies with reported strut‐level data in human subjects evaluated by optical coherence tomography (OCT) surveillance and to compare the aggregate data of stent strut coverage on a longitudinal temporal timeline from initial implantation for different coronary stent subtypes. Background: Delayed strut coverage following drug‐eluting stent (DES) implantation is an important contributor to late stent thrombosis (LST). OCT can detect stent strut coverage. Methods: We conducted a systematic search of published or presented studies reporting OCT stent strut coverage of bare‐metal stents (BMS) and DES in PubMed, Embase, Web of Science, and the Cochrane Central Register of Controlled Trials to June 2014. Data from 3, 515 patients with strut‐level data on 731, 761 struts were analyzed. Results: The temporal kinetics of strut coverage differed according to stent type. The rate of strut coverage, reflected by the calculated regression coefficient, was found to be the highest in BMS, followed by early generation zotarolimus‐eluting stent, everolimus‐eluting stent, newer‐generation zotarolimus‐eluting stent, paclitaxel‐eluting stent, and sirolimus‐eluting stent ( p < 0.0001). Conclusions: Aggregate rates of stent strut coverage assessed by OCT surveillance differed according to stent type. The clinical implications of these differences require further study but may underlie the differences in rates of stent thrombosis observed in clinical trials with different stent types. © 2015 Wiley Periodicals, Inc. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 88:Issue 7(2016)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 88:Issue 7(2016)
- Issue Display:
- Volume 88, Issue 7 (2016)
- Year:
- 2016
- Volume:
- 88
- Issue:
- 7
- Issue Sort Value:
- 2016-0088-0007-0000
- Page Start:
- 1083
- Page End:
- 1093
- Publication Date:
- 2015-12-28
- Subjects:
- stents -- coronary disease -- meta‐analysis
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.26374 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1472.xml