On-site classification of pansteatitis in Mozambique tilapia (Oreochromis mossambicus) using a portable lipid-based analyzer. Issue 36 (17th May 2016)
- Record Type:
- Journal Article
- Title:
- On-site classification of pansteatitis in Mozambique tilapia (Oreochromis mossambicus) using a portable lipid-based analyzer. Issue 36 (17th May 2016)
- Main Title:
- On-site classification of pansteatitis in Mozambique tilapia (Oreochromis mossambicus) using a portable lipid-based analyzer
- Authors:
- Bowden, John A.
Somerville, Stephen E.
Cantu, Theresa M.
Guillette, Matthew P.
Botha, Hannes
Boggs, Ashley S. P.
Luus-Powell, Wilmien
Guillette, Louis J. - Abstract:
- Abstract : On-site application of a portable lipid-based analyzer for total cholesterol measurement of healthy and pansteatitis-affected Mozambique tilapia ( Oreochromis mossambicus ). Abstract : While no pansteatitis-related large-scale mortality events have occurred since 2008, the current status of pansteatitis (presence and pervasiveness) in the Olifants River system and other regions of South Africa remain largely unknown. In part, this is due to both a lack of known biological markers of pansteatitis and a lack of suitable non-invasive assays capable of rapidly classifying the disease. Here, we propose the application of a point-of-care (POC) device using lipid-based test strips (total cholesterol (TC) and total triglyceride (TG)), for classifying pansteatitis status in the whole blood of pre-spawning Mozambique tilapia ( Oreochromis mossambicus ). Using the TC strips, the POC device was able to non-lethally classify the tilapia as either healthy or pansteatitis-affected; the sexes were examined independently because sexual dimorphism was observed for TC (males p = 0.0364, females χ 2 = 0.0007). No significant difference between healthy and pansteatitis-affected tilapia was observed using the TG strips. This is one of the first described applications of using POC devices for on-site environmental disease state testing. A discussion on the merits of using portable lipid-based analyzers as an in-field disease state diagnostic tool is provided.
- Is Part Of:
- Analytical methods. Volume 8:Issue 36(2016)
- Journal:
- Analytical methods
- Issue:
- Volume 8:Issue 36(2016)
- Issue Display:
- Volume 8, Issue 36 (2016)
- Year:
- 2016
- Volume:
- 8
- Issue:
- 36
- Issue Sort Value:
- 2016-0008-0036-0000
- Page Start:
- 6631
- Page End:
- 6635
- Publication Date:
- 2016-05-17
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c6ay00446f ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1957.xml