Osteosynthesis for clavicle fractures: How close are we to penetration of neurovascular structures?. Issue 2 (February 2017)
- Record Type:
- Journal Article
- Title:
- Osteosynthesis for clavicle fractures: How close are we to penetration of neurovascular structures?. Issue 2 (February 2017)
- Main Title:
- Osteosynthesis for clavicle fractures: How close are we to penetration of neurovascular structures?
- Authors:
- Stillwell, A.
Ioannou, C.
Daniele, L.
Tan, S.L.E. - Abstract:
- Abstract: Introduction: Risks associated with drill plunging are well recognised in clavicle osteosynthesis. To date no studies have described plunge depth associated with clavicle osteosynthesis. Primary aim: To determine whether plunge depth associated with clavicle osteosynthesis is great enough to penetrate neurovascular structures and whether surgical experience reduces the risk of neurovascular injury Method: Cadaveric clavicles were pressed into spongy phenolic foam to allow measurement of drill bit penetration beyond the far cortex (plunge depth). 15 surgeons grouped according to experience were asked to drill a single hole in the medial, middle and lateral clavicle in 2 specimens each. Each surgeon used fully a charged standard Stryker drill with a new 2.6 mm drill bit and guide. Plunge depths were measured in 0.5 mm increments. Depth measurements were compared amongst groups and to previously documented distances to neurovascular structures as outlined by Robinson et al. Kruskal-Wallis test was used for overall comparison and Mann-Whitney U test was used for comparing the groups individually. Results: Mean plunge depth across all groups was 3.4 mm, (0.5–6.5), 4.0 mm (1 mm–8.5 mm) and 4.0 mm (0.5mm–15 mm) in the medial, middle and lateral clavicle. Plunge depths were greater than previously documented distances to the subclavian vein at the medial clavicle on nine occasions. Plunge depths in the middle and lateral clavicle were well within the previously documentedAbstract: Introduction: Risks associated with drill plunging are well recognised in clavicle osteosynthesis. To date no studies have described plunge depth associated with clavicle osteosynthesis. Primary aim: To determine whether plunge depth associated with clavicle osteosynthesis is great enough to penetrate neurovascular structures and whether surgical experience reduces the risk of neurovascular injury Method: Cadaveric clavicles were pressed into spongy phenolic foam to allow measurement of drill bit penetration beyond the far cortex (plunge depth). 15 surgeons grouped according to experience were asked to drill a single hole in the medial, middle and lateral clavicle in 2 specimens each. Each surgeon used fully a charged standard Stryker drill with a new 2.6 mm drill bit and guide. Plunge depths were measured in 0.5 mm increments. Depth measurements were compared amongst groups and to previously documented distances to neurovascular structures as outlined by Robinson et al. Kruskal-Wallis test was used for overall comparison and Mann-Whitney U test was used for comparing the groups individually. Results: Mean plunge depth across all groups was 3.4 mm, (0.5–6.5), 4.0 mm (1 mm–8.5 mm) and 4.0 mm (0.5mm–15 mm) in the medial, middle and lateral clavicle. Plunge depths were greater than previously documented distances to the subclavian vein at the medial clavicle on nine occasions. Plunge depths in the middle and lateral clavicle were well within the previously documented distances from neurovascular structures. There was no correlation between level of experience and median plunge depth (p = 0.18). However, inexperienced surgeons plunged 1 mm greater than intermediate and experienced surgeons (p = 0.026). There was one significant outlier; a 15 mm plunge depth by an inexperienced surgeon in the lateral clavicle. Conclusion: Clavicle osteosynthesis has a relatively high risk of neurovascular injury. Plunge depths through the clavicle often exceed the distance of neurovascular structures, especially in the medial clavicle. A thorough understanding of the anatomy of these neurovascular structures and methods to prevent excessive plunging is important prior to undertaking clavicle osteosynthesis. … (more)
- Is Part Of:
- Injury. Volume 48:Issue 2(2017)
- Journal:
- Injury
- Issue:
- Volume 48:Issue 2(2017)
- Issue Display:
- Volume 48, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 48
- Issue:
- 2
- Issue Sort Value:
- 2017-0048-0002-0000
- Page Start:
- 460
- Page End:
- 463
- Publication Date:
- 2017-02
- Subjects:
- Trauma -- Clavicle osteosynthesis -- Plating -- Clavicle fracture -- Internal fixation -- Plunge depth -- Neurovascular injury -- Surgical complication -- Surgical experience
Wounds and injuries -- Surgery -- Periodicals
Accidents -- Periodicals
Wounds and Injuries -- surgery -- Periodicals
Lésions et blessures -- Chirurgie -- Périodiques
Electronic journals
Electronic journals
617.1 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00201383 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00201383 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00201383 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.injury.2016.10.044 ↗
- Languages:
- English
- ISSNs:
- 0020-1383
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4514.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 188.xml