Is device-assisted reduction prior to semi-extended intramedullary nailing of distal tibial fractures necessary?. Issue 2 (February 2017)
- Record Type:
- Journal Article
- Title:
- Is device-assisted reduction prior to semi-extended intramedullary nailing of distal tibial fractures necessary?. Issue 2 (February 2017)
- Main Title:
- Is device-assisted reduction prior to semi-extended intramedullary nailing of distal tibial fractures necessary?
- Authors:
- Mehta, Nisarg
Selvaratnam, Veenesh
Giotakis, Nikolaos
Narayan, Badri - Abstract:
- Abstract: Introduction: Traditional methods of nailing distal tibial fractures have an unacceptable risk of mal-alignment due to difficulty in obtaining and maintaining reduction intra-operatively. Methods to obtain and maintain reduction when nailing these fractures, and therefore reducing the risk of Mal-alignment include modified external fixators, distractors and commercial reduction tools. Semi-extended intramedullary nailing of distal tibial fractures via a supra-patellar approach is now being used more commonly. The aim of this study was to assess whether a commercial reduction device (Staffordshire Orthopaedic Reduction Machine − STORM, Intelligent Orthopaedics, Stafffordshire, UK) is necessary to reduce the risk of mal-alignment in patients undergoing semi-extended nailing for distal tibial fractures. Methodology: A case-control study was conducted in 20 patients who had STORM-assisted reduction of distal tibial fractures prior to intramedullary nailing and 20 controls without STORM. The control group was matched for age, sex, fracture type (AO/OTA), ASA and gender. All patients had an intramedullary nail (IMN) using the semi-extended system. Primary outcome measures were coronal and sagittal mal-alignment. Secondary outcome measure was unplanned return to theatre for complications and problems with fracture healing. Results: There was no difference in post-operative mal-alignment in both groups. There was no significant difference in time to union in both groupsAbstract: Introduction: Traditional methods of nailing distal tibial fractures have an unacceptable risk of mal-alignment due to difficulty in obtaining and maintaining reduction intra-operatively. Methods to obtain and maintain reduction when nailing these fractures, and therefore reducing the risk of Mal-alignment include modified external fixators, distractors and commercial reduction tools. Semi-extended intramedullary nailing of distal tibial fractures via a supra-patellar approach is now being used more commonly. The aim of this study was to assess whether a commercial reduction device (Staffordshire Orthopaedic Reduction Machine − STORM, Intelligent Orthopaedics, Stafffordshire, UK) is necessary to reduce the risk of mal-alignment in patients undergoing semi-extended nailing for distal tibial fractures. Methodology: A case-control study was conducted in 20 patients who had STORM-assisted reduction of distal tibial fractures prior to intramedullary nailing and 20 controls without STORM. The control group was matched for age, sex, fracture type (AO/OTA), ASA and gender. All patients had an intramedullary nail (IMN) using the semi-extended system. Primary outcome measures were coronal and sagittal mal-alignment. Secondary outcome measure was unplanned return to theatre for complications and problems with fracture healing. Results: There was no difference in post-operative mal-alignment in both groups. There was no significant difference in time to union in both groups Both groups had equal number of patients requiring unplanned return to theatre. The STORM group was associated with a significantly increased operative time [p = 0.007, 130.3 min (SD 49.4) STORM vs 95.6 mins (SD 22.9) Control]. Conclusion: Intraoperative use of STORM significantly increases operative time with no difference in outcome. The superior orthogonal views and manual control obtained during semi-extended nailing via a supra-patellar approach obviate the need for additional methods: of intraoperative reduction for this fracture group. … (more)
- Is Part Of:
- Injury. Volume 48:Issue 2(2017)
- Journal:
- Injury
- Issue:
- Volume 48:Issue 2(2017)
- Issue Display:
- Volume 48, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 48
- Issue:
- 2
- Issue Sort Value:
- 2017-0048-0002-0000
- Page Start:
- 506
- Page End:
- 510
- Publication Date:
- 2017-02
- Subjects:
- Distal tibial fracture -- STORM -- Mal-alignment -- Suprapatellar nailing -- Semi-extended approach
Wounds and injuries -- Surgery -- Periodicals
Accidents -- Periodicals
Wounds and Injuries -- surgery -- Periodicals
Lésions et blessures -- Chirurgie -- Périodiques
Electronic journals
Electronic journals
617.1 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00201383 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00201383 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00201383 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.injury.2016.12.002 ↗
- Languages:
- English
- ISSNs:
- 0020-1383
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4514.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 188.xml