Comparison of maximum force to failure of 4 thoracostomy tube connecting devices*. Issue 2 (28th December 2016)
- Record Type:
- Journal Article
- Title:
- Comparison of maximum force to failure of 4 thoracostomy tube connecting devices*. Issue 2 (28th December 2016)
- Main Title:
- Comparison of maximum force to failure of 4 thoracostomy tube connecting devices*
- Authors:
- Psathas, Ιoannis
Papazoglou, Lysimachos G.
Bikiaris, Dimitrios
Savvas, Ioannis
Kazakos, Georgios
Basdani, Eleni - Abstract:
- Abstract: Objective: To compare the maximum force and displacement to failure of 4 different types of thoracostomy tube connecting devices. Study Design: Experimental in vitro study. Study Population : Four types of thoracostomy tube connecting devices (n = 10 each). Methods: Four different connecting device configurations (10 constructs each) were tested by maximum distraction to failure using a dynamometer: (1) CTTWW—a 3‐way connector with a male luer slip attached to a thoracostomy tube by a Christmas tree adapter and secured to the tube with 21 gauge orthopedic wire; (2) CTTWRCW—a 3‐way connector with a male luer lock with a rotating collar attached to a tube by a Christmas tree adapter and secured to the tube with 21 gauge orthopedic wire; (3) LVSBC—a Lopez valve attached to a tube with its short‐barbed connector; and (4) LVLBC—a Lopez valve attached to a tube with its long‐barbed connector. Results: The maximum distraction force to failure was significantly greater for CTTWRCW (250.9 N; range 143.7‐293.6) than CTTWW (132.9 N; range 84.2‐224.1), LVLBC (90.8 N; range 74.0‐123.4), and LVSBC (54.6 N; range 39.6‐164.2). The median displacement to failure of CTTWRCW (150 mm; range 54‐190) was significantly longer than that of CTTWW (34.5 mm; range 22‐70), LVLBC (32.5 mm; range 24‐57), and LVSBC (16 mm; range 11‐69). Conclusion: The CTTWRCW group required greater force to create failure and had a longer displacement to failure, making it a more secure choice for connection toAbstract: Objective: To compare the maximum force and displacement to failure of 4 different types of thoracostomy tube connecting devices. Study Design: Experimental in vitro study. Study Population : Four types of thoracostomy tube connecting devices (n = 10 each). Methods: Four different connecting device configurations (10 constructs each) were tested by maximum distraction to failure using a dynamometer: (1) CTTWW—a 3‐way connector with a male luer slip attached to a thoracostomy tube by a Christmas tree adapter and secured to the tube with 21 gauge orthopedic wire; (2) CTTWRCW—a 3‐way connector with a male luer lock with a rotating collar attached to a tube by a Christmas tree adapter and secured to the tube with 21 gauge orthopedic wire; (3) LVSBC—a Lopez valve attached to a tube with its short‐barbed connector; and (4) LVLBC—a Lopez valve attached to a tube with its long‐barbed connector. Results: The maximum distraction force to failure was significantly greater for CTTWRCW (250.9 N; range 143.7‐293.6) than CTTWW (132.9 N; range 84.2‐224.1), LVLBC (90.8 N; range 74.0‐123.4), and LVSBC (54.6 N; range 39.6‐164.2). The median displacement to failure of CTTWRCW (150 mm; range 54‐190) was significantly longer than that of CTTWW (34.5 mm; range 22‐70), LVLBC (32.5 mm; range 24‐57), and LVSBC (16 mm; range 11‐69). Conclusion: The CTTWRCW group required greater force to create failure and had a longer displacement to failure, making it a more secure choice for connection to thoracostomy tubes. … (more)
- Is Part Of:
- Veterinary surgery. Volume 46:Issue 2(2017)
- Journal:
- Veterinary surgery
- Issue:
- Volume 46:Issue 2(2017)
- Issue Display:
- Volume 46, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 46
- Issue:
- 2
- Issue Sort Value:
- 2017-0046-0002-0000
- Page Start:
- 249
- Page End:
- 254
- Publication Date:
- 2016-12-28
- Subjects:
- Veterinary surgery -- Periodicals
Veterinary Medicine -- Periodicals
Surgery -- Periodicals
Societies, Medical -- Periodicals
636.0897 - Journal URLs:
- http://www.blackwell-synergy.com/loi/vsu ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=vsu ↗
http://www.harcourthealth.com/vetsurg ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0161-3499;screen=info;ECOIP ↗ - DOI:
- 10.1111/vsu.12605 ↗
- Languages:
- English
- ISSNs:
- 0161-3499
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9231.037000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1958.xml