Improvements of Procedural Results With a New‐Generation Self‐Expanding Transfemoral Aortic Valve Prosthesis in Comparison to the Old‐Generation Device. (24th November 2016)
- Record Type:
- Journal Article
- Title:
- Improvements of Procedural Results With a New‐Generation Self‐Expanding Transfemoral Aortic Valve Prosthesis in Comparison to the Old‐Generation Device. (24th November 2016)
- Main Title:
- Improvements of Procedural Results With a New‐Generation Self‐Expanding Transfemoral Aortic Valve Prosthesis in Comparison to the Old‐Generation Device
- Authors:
- Gomes, Bruna
Geis, Nicolas A.
Chorianopoulos, Emmanuel
Meder, Benjamin
Leuschner, Florian
Katus, Hugo A.
Bekeredjian, Raffi - Abstract:
- Abstract : Objectives: In this study, we compare procedural results of our first Evolut R (Medtronic, Minneapolis, MN, USA) implantations with the last CoreValve implantations. Main endpoints include paravalvular regurgitation, major vascular complications, stroke, and pacemaker implantation. Background: The evolution of transcatheter aortic valve replacement (TAVR) was possible due to various technical improvements, leading to better periprocedural and long‐term outcome. The newly designed Evolut R valve has the potential to further improve TAVR's performance. Methods: We retrospectively analyzed our first 100 consecutive patients who received the Evolut R valve with the last 100 consecutive patients who received the CoreValve prosthesis between July 2013 and February 2016. Only patients treated with a 26 mm or 29 mm bioprosthesis were included. Results: No significant differences in patient characteristics were noticed. Both angiography and echocardiography after TAVR showed significantly higher rates of "none or trace" regurgitation in the Evolut R group (angiography: 67% Evolut R vs. 29.3% CoreValve; P < 0.001; echocardiography: 68% Evolut R vs. 46.5% CoreValve; P < 0.05). No significant differences were seen in 30‐day mortality (7% CoreValve vs. 1% Evolut R), stroke rates (3% CoreValve vs. 2% Evolut R), pacemaker implantation rates (24% CoreValve vs. 23% Evolut R), and major vascular complications (6% CoreValve vs. 1% Evolut R). Implantations were significantly higherAbstract : Objectives: In this study, we compare procedural results of our first Evolut R (Medtronic, Minneapolis, MN, USA) implantations with the last CoreValve implantations. Main endpoints include paravalvular regurgitation, major vascular complications, stroke, and pacemaker implantation. Background: The evolution of transcatheter aortic valve replacement (TAVR) was possible due to various technical improvements, leading to better periprocedural and long‐term outcome. The newly designed Evolut R valve has the potential to further improve TAVR's performance. Methods: We retrospectively analyzed our first 100 consecutive patients who received the Evolut R valve with the last 100 consecutive patients who received the CoreValve prosthesis between July 2013 and February 2016. Only patients treated with a 26 mm or 29 mm bioprosthesis were included. Results: No significant differences in patient characteristics were noticed. Both angiography and echocardiography after TAVR showed significantly higher rates of "none or trace" regurgitation in the Evolut R group (angiography: 67% Evolut R vs. 29.3% CoreValve; P < 0.001; echocardiography: 68% Evolut R vs. 46.5% CoreValve; P < 0.05). No significant differences were seen in 30‐day mortality (7% CoreValve vs. 1% Evolut R), stroke rates (3% CoreValve vs. 2% Evolut R), pacemaker implantation rates (24% CoreValve vs. 23% Evolut R), and major vascular complications (6% CoreValve vs. 1% Evolut R). Implantations were significantly higher with the Evolut R prosthesis. Conclusions: TAVR with the new Evolut R resulted in significantly lower paravalvular regurgitation. This may be due to redesigned cell geometry and higher precision during implantations, as well as the ability to resheath a malpositioned valve. … (more)
- Is Part Of:
- Journal of interventional cardiology. Volume 30:Number 1(2017:Feb.)
- Journal:
- Journal of interventional cardiology
- Issue:
- Volume 30:Number 1(2017:Feb.)
- Issue Display:
- Volume 30, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 30
- Issue:
- 1
- Issue Sort Value:
- 2017-0030-0001-0000
- Page Start:
- 72
- Page End:
- 78
- Publication Date:
- 2016-11-24
- Subjects:
- Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.1206 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8183 ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=joic ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/joic.12356 ↗
- Languages:
- English
- ISSNs:
- 0896-4327
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5007.696000
British Library STI - ELD Digital store - Ingest File:
- 1916.xml