HYKL-40 cancer biomarker electroanalysis in serum samples and model cell lysates: capacitive immunosensing compared with enzyme label immunosorbent assays (ELISA). Issue 3 (20th January 2017)
- Record Type:
- Journal Article
- Title:
- HYKL-40 cancer biomarker electroanalysis in serum samples and model cell lysates: capacitive immunosensing compared with enzyme label immunosorbent assays (ELISA). Issue 3 (20th January 2017)
- Main Title:
- HYKL-40 cancer biomarker electroanalysis in serum samples and model cell lysates: capacitive immunosensing compared with enzyme label immunosorbent assays (ELISA)
- Authors:
- Chaocharoen, W.
Schulte, A.
Suginta, W. - Abstract:
- Abstract : The first electrochemical analysis of molecular cancer biomarker h YKL-40 in blood serum samples of breast and brain tumor patients via capacitive immunosensing. Abstract : Human chitinase 3-like protein 1 (CHI3L1 or h YKL-40 ), a potential molecular marker for several cancers, was measured in clinical human serum samples and model cell lysates by indirect and competitive enzyme-linked immunosorbent assay (ELISA) and by capacitive immunosensing, so as to evaluate a recently introduced electrochemical method for routine use in cancer-monitoring studies. The clinical samples tested included serum from four healthy individuals, five breast cancer and four glioblastoma patients; cultures of the human monocytic cell line THP-1, known to secrete h YKL-40, and of the human embryonic kidney 293t cell line, which does not express h YKL-40, provided cell lysates and cell culture media for positive and negative bio- and electrochemical control trials. A good agreement was observed between the results of the three tested methods during h YKL-40 quantifications in human serum and cell lysates. Measurements of 'spiked' samples from healthy volunteers, cancer patients and h YKL-40 -free 293t cell lysates revealed that capacitive immunosensing and the two types of ELISA all recovered the analyte with an efficiency close to 100%. On this basis, capacitive h YKL-40 immunosensor screening is a promising stand-alone or complementary analytical tool for the analysis of h YKL-40 inAbstract : The first electrochemical analysis of molecular cancer biomarker h YKL-40 in blood serum samples of breast and brain tumor patients via capacitive immunosensing. Abstract : Human chitinase 3-like protein 1 (CHI3L1 or h YKL-40 ), a potential molecular marker for several cancers, was measured in clinical human serum samples and model cell lysates by indirect and competitive enzyme-linked immunosorbent assay (ELISA) and by capacitive immunosensing, so as to evaluate a recently introduced electrochemical method for routine use in cancer-monitoring studies. The clinical samples tested included serum from four healthy individuals, five breast cancer and four glioblastoma patients; cultures of the human monocytic cell line THP-1, known to secrete h YKL-40, and of the human embryonic kidney 293t cell line, which does not express h YKL-40, provided cell lysates and cell culture media for positive and negative bio- and electrochemical control trials. A good agreement was observed between the results of the three tested methods during h YKL-40 quantifications in human serum and cell lysates. Measurements of 'spiked' samples from healthy volunteers, cancer patients and h YKL-40 -free 293t cell lysates revealed that capacitive immunosensing and the two types of ELISA all recovered the analyte with an efficiency close to 100%. On this basis, capacitive h YKL-40 immunosensor screening is a promising stand-alone or complementary analytical tool for the analysis of h YKL-40 in serum, and would be useful for the validation of standard ELISA data and also, because of the significantly lower h YKL-40 detection limit of the electroanalytical procedure, would permit assay of the marker and cancer observation at earlier stages than is currently possible using ELISA. … (more)
- Is Part Of:
- Analyst. Volume 142:Issue 3(2017)
- Journal:
- Analyst
- Issue:
- Volume 142:Issue 3(2017)
- Issue Display:
- Volume 142, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 142
- Issue:
- 3
- Issue Sort Value:
- 2017-0142-0003-0000
- Page Start:
- 503
- Page End:
- 510
- Publication Date:
- 2017-01-20
- Subjects:
- Chemistry, Analytic -- Periodicals
543 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/an?e=1#!issueid=an139020&type=current&issnprint=0003-2654 ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c6an02239a ↗
- Languages:
- English
- ISSNs:
- 0003-2654
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0893.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1127.xml