Anisotropic abdominal aortic aneurysm replicas with biaxial material characterization. Issue 12 (December 2016)
- Record Type:
- Journal Article
- Title:
- Anisotropic abdominal aortic aneurysm replicas with biaxial material characterization. Issue 12 (December 2016)
- Main Title:
- Anisotropic abdominal aortic aneurysm replicas with biaxial material characterization
- Authors:
- Ruiz de Galarreta, Sergio
Antón, Raúl
Cazon, Aitor
Larraona, Gorka S.
Finol, Ender A. - Abstract:
- Highlights: Manufacturing of non-uniform wall thickness and anisotropic AAA replicas. Biaxial testing of composite specimens. Mathematical model of composite and phantom specimens. Abstract: An Abdominal Aortic Aneurysm (AAA) is a permanent focal dilatation of the abdominal aorta at least 1.5 times its normal diameter. The criterion of maximum diameter is still used in clinical practice, although numerical studies have demonstrated the importance of other biomechanical factors. Numerical studies, however, must be validated experimentally before they can be clinically implemented. We have developed a methodology for manufacturing anisotropic AAA replicas with non-uniform wall thickness. Different composites were fabricated and tested, and one was selected in order to manufacture a phantom with the same properties. The composites and the phantom were characterized by biaxial tensile tests and a material model was fit to the experimental data. The experimental results were compared with data from the literature, and similar responses were obtained. The anisotropic AAA replicas with non-uniform wall thickness can be used in benchtop experiments to validate deformations obtained with numerical simulations or for pre-intervention testing of endovascular grafts. This is a significant step forward considering the importance of anisotropy in numerical simulations.
- Is Part Of:
- Medical engineering & physics. Volume 38:Issue 12(2016:Dec.)
- Journal:
- Medical engineering & physics
- Issue:
- Volume 38:Issue 12(2016:Dec.)
- Issue Display:
- Volume 38, Issue 12 (2016)
- Year:
- 2016
- Volume:
- 38
- Issue:
- 12
- Issue Sort Value:
- 2016-0038-0012-0000
- Page Start:
- 1505
- Page End:
- 1512
- Publication Date:
- 2016-12
- Subjects:
- Anisotropy -- AAA phantom -- Biaxial -- Stereovision -- Vacuum casting -- Additive manufacturing
Biomedical engineering -- Periodicals
Biomedical Engineering -- Periodicals
Physics -- Periodicals
Génie biomédical -- Périodiques
Biomedical engineering
Electronic journals
Periodicals
610.28 - Journal URLs:
- http://www.medengphys.com ↗
http://www.sciencedirect.com/science/journal/13504533 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13504533 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13504533 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.medengphy.2016.09.010 ↗
- Languages:
- English
- ISSNs:
- 1350-4533
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5527.323000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1790.xml