Push-out tests for perfobond strip connectors with UHPC grout in the joints of steel-concrete hybrid bridge girders. (15th March 2017)
- Record Type:
- Journal Article
- Title:
- Push-out tests for perfobond strip connectors with UHPC grout in the joints of steel-concrete hybrid bridge girders. (15th March 2017)
- Main Title:
- Push-out tests for perfobond strip connectors with UHPC grout in the joints of steel-concrete hybrid bridge girders
- Authors:
- He, Shaohua
Fang, Zhi
Mosallam, Ayman S. - Abstract:
- Highlights: The structural behavior of PBL using UHPC is studied by push-out tests. The impact of steel fibers content in UHPC on the behavior of PBL is studied. The shear-resistant capacity of the PBL embedded in UHPC grout is analyzed. Equations to predict the shear capacity of PBL in steel-concrete joint are proposed. Abstract: This paper aims at examining the structural behavior of perfobond strip ( PBL ) connectors for steel-concrete joint of hybrid girders with ultra-high performance concrete ( UHPC ) as grout for such connectors. Twenty-four push-out specimens fabricated according to the design used for the connectors in the steel-concrete joint in a hybrid cable-stayed bridge have been investigated. Effects of several parameters such as (i) the interface bond between perforated plate and concrete, (ii) dowels inside the holes in the plate, and (iii) volume of steel fibers in the UHPC on the behavior of PBL were discussed in depth. Experimental results indicated that the use of a 2% volume fraction of steel fibers in the UHPC, increased the average bond strength at the plate/concrete interface and the shear resistant-capacity of concrete dowel by 82% and 50%, respectively, as compared to UHPC specimens without the fibers. The concrete dowel played an important role in developing the desired loading resistant-capacity of the PBL, and about 34–41% of the overall resistance of a standard PBL embedded in UHPC were supplied by the concrete dowel surrounding transverseHighlights: The structural behavior of PBL using UHPC is studied by push-out tests. The impact of steel fibers content in UHPC on the behavior of PBL is studied. The shear-resistant capacity of the PBL embedded in UHPC grout is analyzed. Equations to predict the shear capacity of PBL in steel-concrete joint are proposed. Abstract: This paper aims at examining the structural behavior of perfobond strip ( PBL ) connectors for steel-concrete joint of hybrid girders with ultra-high performance concrete ( UHPC ) as grout for such connectors. Twenty-four push-out specimens fabricated according to the design used for the connectors in the steel-concrete joint in a hybrid cable-stayed bridge have been investigated. Effects of several parameters such as (i) the interface bond between perforated plate and concrete, (ii) dowels inside the holes in the plate, and (iii) volume of steel fibers in the UHPC on the behavior of PBL were discussed in depth. Experimental results indicated that the use of a 2% volume fraction of steel fibers in the UHPC, increased the average bond strength at the plate/concrete interface and the shear resistant-capacity of concrete dowel by 82% and 50%, respectively, as compared to UHPC specimens without the fibers. The concrete dowel played an important role in developing the desired loading resistant-capacity of the PBL, and about 34–41% of the overall resistance of a standard PBL embedded in UHPC were supplied by the concrete dowel surrounding transverse rebar. The source of the achieved ductility of PBL was mainly determined by the action of transverse rebars, and the ductility in the specimens having transverse rebars was about eleven times the ductility of similar specimens without the rebars. Furthermore, the experimental ultimate strength values of PBL were compared with available equations in literatures published recently, and an analytical model for PBL/UHPC was developed and appropriate parameters were derived from present data and used to provide reliable prediction of ultimate resistant-capacity of PBL in the hybrid girders' steel-concrete joints. … (more)
- Is Part Of:
- Engineering structures. Volume 135(2017:Mar. 15)
- Journal:
- Engineering structures
- Issue:
- Volume 135(2017:Mar. 15)
- Issue Display:
- Volume 135 (2017)
- Year:
- 2017
- Volume:
- 135
- Issue Sort Value:
- 2017-0135-0000-0000
- Page Start:
- 177
- Page End:
- 190
- Publication Date:
- 2017-03-15
- Subjects:
- Perfobond strip connector -- Steel-concrete joints -- Ultra-high performance concrete (UHPC) -- Ultimate strength -- Push-out tests
Structural engineering -- Periodicals
Structural analysis (Engineering) -- Periodicals
Construction, Technique de la -- Périodiques
Génie parasismique -- Périodiques
Pression du vent -- Périodiques
Earthquake engineering
Structural engineering
Wind-pressure
Periodicals
624.105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01410296 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.engstruct.2017.01.008 ↗
- Languages:
- English
- ISSNs:
- 0141-0296
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3770.032000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2625.xml