Seismic reliability of legged wine storage tanks retrofitted by means of a seismic isolation device. (1st March 2017)
- Record Type:
- Journal Article
- Title:
- Seismic reliability of legged wine storage tanks retrofitted by means of a seismic isolation device. (1st March 2017)
- Main Title:
- Seismic reliability of legged wine storage tanks retrofitted by means of a seismic isolation device
- Authors:
- Colombo, J.I.
Almazán, J.L. - Abstract:
- Highlights: The seismic reliability of two typical legged wine storage tanks is investigated. Probability of occurrence of the limit state is reduced through seismic isolation. A novel seismic isolation system is proposed for legged wine storage tanks. Abstract: Due to the booming of the winery industry in some seismic countries such as, the U.S, Italy, New Zealand, Chile and Argentina, the seismic protection of wine storage tanks may be of a practical importance. Wine storage tanks are classified in two major groups: continuously supported tanks and legged tanks. Previous research has described the seismic reliability of continuously-supported tanks, with and without seismic protection devices. Conversely, the seismic reliability of legged wine tanks has not been reported. Therefore, in this study, the seismic reliabilities of two typical stainless steel legged wine storage tanks (one of 3000 L capacity and one of 17, 100 L capacity), used for fermentation and wine storage, in original and updated states are assessed by means of simulation. For the updated state, a non-linear isolation system for seismic isolation of legged wine tanks is used. The effect of the isolation system was numerically estimated by performing a group of non-linear time history analyses for each tank. Each non-linear time history analysis was obtained by means of a mathematical model. A set of different seismic ground motions was used for the purpose of obtaining robust results in the reliabilityHighlights: The seismic reliability of two typical legged wine storage tanks is investigated. Probability of occurrence of the limit state is reduced through seismic isolation. A novel seismic isolation system is proposed for legged wine storage tanks. Abstract: Due to the booming of the winery industry in some seismic countries such as, the U.S, Italy, New Zealand, Chile and Argentina, the seismic protection of wine storage tanks may be of a practical importance. Wine storage tanks are classified in two major groups: continuously supported tanks and legged tanks. Previous research has described the seismic reliability of continuously-supported tanks, with and without seismic protection devices. Conversely, the seismic reliability of legged wine tanks has not been reported. Therefore, in this study, the seismic reliabilities of two typical stainless steel legged wine storage tanks (one of 3000 L capacity and one of 17, 100 L capacity), used for fermentation and wine storage, in original and updated states are assessed by means of simulation. For the updated state, a non-linear isolation system for seismic isolation of legged wine tanks is used. The effect of the isolation system was numerically estimated by performing a group of non-linear time history analyses for each tank. Each non-linear time history analysis was obtained by means of a mathematical model. A set of different seismic ground motions was used for the purpose of obtaining robust results in the reliability analysis. Finally, the seismic reliability analysis shows that, for steel legged wine storage tanks, the effect of the isolation system would reduce the limit state probability in the order of 90%. … (more)
- Is Part Of:
- Engineering structures. Volume 134(2017:Mar. 01)
- Journal:
- Engineering structures
- Issue:
- Volume 134(2017:Mar. 01)
- Issue Display:
- Volume 134 (2017)
- Year:
- 2017
- Volume:
- 134
- Issue Sort Value:
- 2017-0134-0000-0000
- Page Start:
- 303
- Page End:
- 316
- Publication Date:
- 2017-03-01
- Subjects:
- Seismic isolation -- Seismic reliability analysis -- Wine storage tanks -- Fragility curves
Structural engineering -- Periodicals
Structural analysis (Engineering) -- Periodicals
Construction, Technique de la -- Périodiques
Génie parasismique -- Périodiques
Pression du vent -- Périodiques
Earthquake engineering
Structural engineering
Wind-pressure
Periodicals
624.105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01410296 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.engstruct.2016.12.058 ↗
- Languages:
- English
- ISSNs:
- 0141-0296
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3770.032000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1337.xml