Achilles tendon morphology, plantar flexors torque and passive ankle stiffness in spastic hemiparetic stroke survivors. (January 2017)
- Record Type:
- Journal Article
- Title:
- Achilles tendon morphology, plantar flexors torque and passive ankle stiffness in spastic hemiparetic stroke survivors. (January 2017)
- Main Title:
- Achilles tendon morphology, plantar flexors torque and passive ankle stiffness in spastic hemiparetic stroke survivors
- Authors:
- Freire, Bruno
Dias, Caroline Pieta
Goulart, Natália Batista Albuquerque
de Castro, Camila Dias
Becker, Jefferson
Gomes, Irênio
Vaz, Marco Aurélio - Abstract:
- Abstract: Background: The present study compared the Achilles tendon morphological characteristics, plantar flexor toque and passive ankle stiffness between hemiparetic spastic stroke survivors and healthy subjects. Methods: The Achilles tendon length was measured at the affected and contralateral limbs of twelve hemiparetic stroke survivors with ankle spasticity and twelve healthy subjects. The ankle was held at three different angles (20° plantar flexion, 0° and maximum dorsiflexion) while an ultrasound system was used to capture images from the Achilles tendon. Active and passive plantar flexor torque production was measured using an isokinetic dynamometer. Findings: There was no significant difference in tendon length and Achilles tendon complacency between stroke survivors [affected limb: 20.8 (1.59) cm at 0° and 0.11 (0.09) cm/N; contralateral limb: 20.8 (1.7) cm at 0° and 0.12 (0.08) cm/N] and healthy subjects [20 (2.78) cm at 0° and 0.15 (0.1) cm/N]. The contralateral limb was stronger than the affected limb, while healthy participants presented larger active torque in relation to stroke survivors. There was no significant difference in passive ankle stiffness between the affected [0.43 (0.08) N/°] and the contralateral limb [0.40 (0.11) N/°], but affected limb was significantly stiffer than the healthy subjects [0.32 (0.07) N/°]. Interpretation: The larger passive torque and ankle joint stiffness from stroke survivors with similar Achilles tendon length compared toAbstract: Background: The present study compared the Achilles tendon morphological characteristics, plantar flexor toque and passive ankle stiffness between hemiparetic spastic stroke survivors and healthy subjects. Methods: The Achilles tendon length was measured at the affected and contralateral limbs of twelve hemiparetic stroke survivors with ankle spasticity and twelve healthy subjects. The ankle was held at three different angles (20° plantar flexion, 0° and maximum dorsiflexion) while an ultrasound system was used to capture images from the Achilles tendon. Active and passive plantar flexor torque production was measured using an isokinetic dynamometer. Findings: There was no significant difference in tendon length and Achilles tendon complacency between stroke survivors [affected limb: 20.8 (1.59) cm at 0° and 0.11 (0.09) cm/N; contralateral limb: 20.8 (1.7) cm at 0° and 0.12 (0.08) cm/N] and healthy subjects [20 (2.78) cm at 0° and 0.15 (0.1) cm/N]. The contralateral limb was stronger than the affected limb, while healthy participants presented larger active torque in relation to stroke survivors. There was no significant difference in passive ankle stiffness between the affected [0.43 (0.08) N/°] and the contralateral limb [0.40 (0.11) N/°], but affected limb was significantly stiffer than the healthy subjects [0.32 (0.07) N/°]. Interpretation: The larger passive torque and ankle joint stiffness from stroke survivors with similar Achilles tendon length compared to healthy subjects seem to be unrelated to tendon extensibility. Highlights: Spastic stroke survivors had similar Achilles tendon length compared to healthy individuals. Spastic stroke survivors had higher passive torque compared to healthy subjects. Affected and unaffected limbs had similar passive torque. Ankle joint stiffness from stroke survivors seem to be unrelated to tendon extensibility. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 41(2017)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 41(2017)
- Issue Display:
- Volume 41, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 41
- Issue:
- 2017
- Issue Sort Value:
- 2017-0041-2017-0000
- Page Start:
- 72
- Page End:
- 76
- Publication Date:
- 2017-01
- Subjects:
- Ultrasonography -- Muscle strength -- Dynamometer -- Tendons -- Muscle spasticity
Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2016.12.004 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1703.xml