Echocardiographic assessment of prosthetic mitral valves in children. Issue 1 (2nd November 2016)
- Record Type:
- Journal Article
- Title:
- Echocardiographic assessment of prosthetic mitral valves in children. Issue 1 (2nd November 2016)
- Main Title:
- Echocardiographic assessment of prosthetic mitral valves in children
- Authors:
- Hayashi, Taiyu
Inuzuka, Ryo
Ono, Hiroshi
Kato, Hitoshi - Abstract:
- Abstract : Aims: We studied how Doppler‐derived hemodynamic parameters in children change as the relative prosthetic mitral valve (PMV) size decreases with somatic growth and evaluated the diagnostic utility of the parameters for detecting PMV obstruction in children. Methods and Results: We reviewed 26 echocardiographic examination results of 15 mechanical bileaflet PMVs in 12 children. The median age at echocardiographic examination was 6.6 (0.6–18.1) years. The PMV functioned normally in 24 examinations but was obstructed due to thrombosis in two cases. PMV sizes ranged between 16 and 25 mm, which were standardized to body surface area (BSA) at the examination with z‐score calculations. We assessed the peak E velocity, mean pressure gradient (PG), and pressure half time (PHT) of the transprosthetic flow, the velocity–time integral (VTI) ratio of the PMV inflow to the left ventricular outflow, and the BSA‐indexed effective orifice area (iEOA) of the PMV calculated with the continuity equation. Linear regression analysis revealed statistically significant correlations between all parameters of normally functioning PMVs and the PMV size z‐scores (Pearson correlation coefficients: peak E velocity, −0.68; mean PG, −0.71; PHT, −0.82; VTI ratio, −0.76; iEOA, 0.79). Compared with the predictive values derived from the regression equations, the VTI ratio and iEOA exceeded ± 2 standard errors in both patients with obstructive PMVs. Conclusion: To assess PMV function in children,Abstract : Aims: We studied how Doppler‐derived hemodynamic parameters in children change as the relative prosthetic mitral valve (PMV) size decreases with somatic growth and evaluated the diagnostic utility of the parameters for detecting PMV obstruction in children. Methods and Results: We reviewed 26 echocardiographic examination results of 15 mechanical bileaflet PMVs in 12 children. The median age at echocardiographic examination was 6.6 (0.6–18.1) years. The PMV functioned normally in 24 examinations but was obstructed due to thrombosis in two cases. PMV sizes ranged between 16 and 25 mm, which were standardized to body surface area (BSA) at the examination with z‐score calculations. We assessed the peak E velocity, mean pressure gradient (PG), and pressure half time (PHT) of the transprosthetic flow, the velocity–time integral (VTI) ratio of the PMV inflow to the left ventricular outflow, and the BSA‐indexed effective orifice area (iEOA) of the PMV calculated with the continuity equation. Linear regression analysis revealed statistically significant correlations between all parameters of normally functioning PMVs and the PMV size z‐scores (Pearson correlation coefficients: peak E velocity, −0.68; mean PG, −0.71; PHT, −0.82; VTI ratio, −0.76; iEOA, 0.79). Compared with the predictive values derived from the regression equations, the VTI ratio and iEOA exceeded ± 2 standard errors in both patients with obstructive PMVs. Conclusion: To assess PMV function in children, Doppler‐derived hemodynamic parameters should be compared with their predictive values based on relative PMV sizes. The deviation of the VTI ratio and iEOA from their predictive values may indicate prosthetic obstruction. … (more)
- Is Part Of:
- Echocardiography. Volume 34:Issue 1(2017)
- Journal:
- Echocardiography
- Issue:
- Volume 34:Issue 1(2017)
- Issue Display:
- Volume 34, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 34
- Issue:
- 1
- Issue Sort Value:
- 2017-0034-0001-0000
- Page Start:
- 94
- Page End:
- 101
- Publication Date:
- 2016-11-02
- Subjects:
- Doppler echocardiography -- mitral valve prosthesis -- thrombus
Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.13406 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2270.xml