Comparison between circular and square loops for low‐frequency magnetic resonance applications: theoretical performance estimation. Issue 3 (18th October 2016)
- Record Type:
- Journal Article
- Title:
- Comparison between circular and square loops for low‐frequency magnetic resonance applications: theoretical performance estimation. Issue 3 (18th October 2016)
- Main Title:
- Comparison between circular and square loops for low‐frequency magnetic resonance applications: theoretical performance estimation
- Authors:
- Giovannetti, Giulio
- Abstract:
- Abstract: Radiofrequency receiver coils in magnetic resonance (MR) systems are used to pick up the signals emitted by the nuclei with high signal‐to‐noise ratio (SNR) in a small region of sensitivity. The quality of obtained images strongly depends upon the correct choice of the coils geometry and size. The simplest design of such coils is circular and square loops, both producing in the central region‐of‐interest a magnetic field perpendicular to the coil plane, with an amplitude that decreases along the coil axis. This work reviews a method for coil SNR model development employing an equivalent electric circuit and applies it for circular and square loop design. Coil inductance and resistance were analitically calculated by taking into account for the conductors cross‐geometry and the magnetic field pattern was estimated using Biot–Savart law, while the sample‐induced resistance was calculated with a method employing a quasi‐static approach. Coil performance prediction permitted to compare circular and square loops and demonstrated that when a simple relationship between loops size is satisfied, the performance of both coils resulted to be very similar in terms of SNR. Since the theoretical approach formulation is largely detailed, this article could be interesting for graduate students and researchers working in the field of MR coil design and development.
- Is Part Of:
- Concepts in magnetic resonance. Volume 46B:Issue 3(2016)
- Journal:
- Concepts in magnetic resonance
- Issue:
- Volume 46B:Issue 3(2016)
- Issue Display:
- Volume 46B, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 46B
- Issue:
- 3
- Issue Sort Value:
- 2016-NaN-0003-0000
- Page Start:
- 146
- Page End:
- 155
- Publication Date:
- 2016-10-18
- Subjects:
- inductance -- radiofrequency coils -- resistance -- signal‐to‐noise ratio
Magnetic resonance -- Periodicals
Nuclear magnetic resonance -- Periodicals
Biomedical engineering -- Periodicals
Magnetic Resonance Spectroscopy -- Periodicals
538.36 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1552-504X ↗
https://www.hindawi.com/journals/cmrb/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/cmr.b.21343 ↗
- Languages:
- English
- ISSNs:
- 1552-5031
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3399.413430
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2133.xml