Three-dimensional stereophotogrammetry as an accurate tool for analyzing lymphedema of the hand. (December 2016)
- Record Type:
- Journal Article
- Title:
- Three-dimensional stereophotogrammetry as an accurate tool for analyzing lymphedema of the hand. (December 2016)
- Main Title:
- Three-dimensional stereophotogrammetry as an accurate tool for analyzing lymphedema of the hand
- Authors:
- Hoevenaren, Inge A.
Verhulst, A.C.
Hameeteman, M.
Vreeken, R.D.
Maal, Thomas J.J.
Ulrich, D.J.O. - Abstract:
- Abstract: Background: Lymphedema of the upper extremity is a frequently observed manifestation following breast cancer surgery. Three-dimensional (3D) stereophotogrammetry is a reliable technique that is used in clinical practice, for example, in volume measurements. This study aimed to investigate if 3D imaging can be used as a reproducible and useful tool for qualifying and quantifying lymphedema of the hand. Methods: A total of 18 patients with unilateral lymphedema of the hand (mean age 56.5 years, 5 left- and 10 right-sided edema) were included. Three-dimensional (3D) photographs of both hands of each individual were captured, and volumes were calculated using 3D computer software programs. The 3D images of the lymphedema hand were compared with the images of the normal unaffected hand in the same patient. The resulting volume difference was linked with the patients' self-reported discomfort. In addition, the normal variance in hand volume was calculated in 15 healthy subjects. Results: After analyzing the hand volumes of all patients with lymphedema, a significantly larger volume was found on the affected side compared with the normal hand of the patients with self-reported discomfort. This difference was larger than that between both the healthy hands of the control subjects. Conclusions: This pilot study shows that 3D photography is a reproducible and useful tool in volume measurements of edematous hands. Changes in hand volume can be easily detected, thus creatingAbstract: Background: Lymphedema of the upper extremity is a frequently observed manifestation following breast cancer surgery. Three-dimensional (3D) stereophotogrammetry is a reliable technique that is used in clinical practice, for example, in volume measurements. This study aimed to investigate if 3D imaging can be used as a reproducible and useful tool for qualifying and quantifying lymphedema of the hand. Methods: A total of 18 patients with unilateral lymphedema of the hand (mean age 56.5 years, 5 left- and 10 right-sided edema) were included. Three-dimensional (3D) photographs of both hands of each individual were captured, and volumes were calculated using 3D computer software programs. The 3D images of the lymphedema hand were compared with the images of the normal unaffected hand in the same patient. The resulting volume difference was linked with the patients' self-reported discomfort. In addition, the normal variance in hand volume was calculated in 15 healthy subjects. Results: After analyzing the hand volumes of all patients with lymphedema, a significantly larger volume was found on the affected side compared with the normal hand of the patients with self-reported discomfort. This difference was larger than that between both the healthy hands of the control subjects. Conclusions: This pilot study shows that 3D photography is a reproducible and useful tool in volume measurements of edematous hands. Changes in hand volume can be easily detected, thus creating an opportunity for the timely initiation of treatment options and simplifying the follow-up process. … (more)
- Is Part Of:
- JPRAS open. Volume 10(2016)
- Journal:
- JPRAS open
- Issue:
- Volume 10(2016)
- Issue Display:
- Volume 10, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 10
- Issue:
- 2016
- Issue Sort Value:
- 2016-0010-2016-0000
- Page Start:
- 40
- Page End:
- 46
- Publication Date:
- 2016-12
- Subjects:
- Breast cancer surgery -- Three-dimensional imaging -- Lymphedema -- Hand surgery -- 3D stereophotogrammetry
Surgery, Plastic -- Great Britain -- Periodicals
617.9505 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23525878 ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.jpra.2016.07.002 ↗
- Languages:
- English
- ISSNs:
- 2352-5878
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1198.xml