Limitations of the TheraMon®‐microsensor in monitoring occlusion therapy. (27th June 2016)
- Record Type:
- Journal Article
- Title:
- Limitations of the TheraMon®‐microsensor in monitoring occlusion therapy. (27th June 2016)
- Main Title:
- Limitations of the TheraMon®‐microsensor in monitoring occlusion therapy
- Authors:
- Schramm, Charlotte
Abaza, Annegret
Blumenstock, Gunnar
Bechtold, Till E.
Rickmann, Annekatrin
Bartz‐Schmidt, Karl‐Ulrich
Besch, Dorothea
Januschowski, Kai - Abstract:
- Abstract: Purpose: A proof of principle study showed that the TheraMon ® ‐microsensor can reliably measure wearing times of glasses and occlusion patches while having no discomfort for the bearer. The goal of this study was to identify specific temperature profiles in a larger patient group wearing the microsensor with an occlusion patch on the eye, the forehead or in the trouser pocket. Methods: Temperature measurements with microsensors were performed at the orbital rim of the eye, at the forehead and in a trousers pocket of 20 healthy adults. The temperature measurements were analysed comparing the three locations using a repeated‐measuresanova with a 0.050 two‐sided significance level. Results: There was no significant temperature difference in wearing the microsensors at the orbital rim compared to forehead (p = 0.507). A significant difference could be detected if the microsensors had been in trousers pockets as compared to being positioned at orbital rim/forehead (p = 0.001). The study participants reported easy handling and comfortable wearing. Conclusion: This study demonstrates for the first time that TheraMon ® ‐microsensors are fully operational in monitoring occlusion therapy in a larger group of patients (20 adult study participants). Because of the microsensor's ease of handling further studies in a larger group of children is recommended.
- Is Part Of:
- Acta ophthalmologica. Volume 94:Number 8(2016)
- Journal:
- Acta ophthalmologica
- Issue:
- Volume 94:Number 8(2016)
- Issue Display:
- Volume 94, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 94
- Issue:
- 8
- Issue Sort Value:
- 2016-0094-0008-0000
- Page Start:
- e753
- Page End:
- e756
- Publication Date:
- 2016-06-27
- Subjects:
- amblyopia -- compliance -- microsensor -- monitoring -- occlusion patch
Ophthalmology -- Periodicals
617.7005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1755-3768 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/aos.13134 ↗
- Languages:
- English
- ISSNs:
- 1755-375X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0641.750500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1281.xml