Fundus autofluorescence lifetimes are increased in non‐proliferative diabetic retinopathy. Issue 1 (13th August 2016)
- Record Type:
- Journal Article
- Title:
- Fundus autofluorescence lifetimes are increased in non‐proliferative diabetic retinopathy. Issue 1 (13th August 2016)
- Main Title:
- Fundus autofluorescence lifetimes are increased in non‐proliferative diabetic retinopathy
- Authors:
- Schmidt, Johanna
Peters, Sven
Sauer, Lydia
Schweitzer, Dietrich
Klemm, Matthias
Augsten, Regine
Müller, Nicolle
Hammer, Martin - Abstract:
- Abstract: Purpose: To discriminate non‐proliferative diabetic retinopathy (NPDR) patients from healthy controls by fluorescence lifetime imaging ophthalmoscopy (FLIO). Methods: A prototype FLIO (Heidelberg‐Engineering, Heidelberg, Germany) was used to examine the retina of 33 patients and 28 controls. As increased fluorescence of the diabetic lens is known, the lenses of 34 patients and 24 controls were investigated as well. Time‐resolved decay was detected in two spectral channels (ch1: 498–560 nm, ch2: 560–720 nm) and approximated by a series of three exponential functions yielding in lifetimes ( τ 1, τ 2, τ 3 ), amplitudes ( α 1, α 2, α 3 ) and their amplitude‐weighted means ( τ m ). Results: Significant differences between patients and controls were found for all fundus lifetime components ( τ m, τ 1 ‐ τ 3 ) as for the amplitude α 3 in both spectral channels. Channel 1 showed the largest differences: the average of mean fluorescence lifetime τ m in the macula was 259 ± 137 ps in the patients versus 147 ± 69 ps in the controls. A logistic regression model allowed discrimination between study and control group with a sensitivity of 90.09% and a specificity of 71.4% (area under the curve: 0.865). Significantly shorter τ m in the patients group than in the control group was detected in channel 2 in the crystalline lens (1587 ± 326 ps versus 1854 ± 384 ps, p = 0.006). Conclusions: Fundus Fluorescence lifetimes are significantly increased in NPDR while lens lifetimes areAbstract: Purpose: To discriminate non‐proliferative diabetic retinopathy (NPDR) patients from healthy controls by fluorescence lifetime imaging ophthalmoscopy (FLIO). Methods: A prototype FLIO (Heidelberg‐Engineering, Heidelberg, Germany) was used to examine the retina of 33 patients and 28 controls. As increased fluorescence of the diabetic lens is known, the lenses of 34 patients and 24 controls were investigated as well. Time‐resolved decay was detected in two spectral channels (ch1: 498–560 nm, ch2: 560–720 nm) and approximated by a series of three exponential functions yielding in lifetimes ( τ 1, τ 2, τ 3 ), amplitudes ( α 1, α 2, α 3 ) and their amplitude‐weighted means ( τ m ). Results: Significant differences between patients and controls were found for all fundus lifetime components ( τ m, τ 1 ‐ τ 3 ) as for the amplitude α 3 in both spectral channels. Channel 1 showed the largest differences: the average of mean fluorescence lifetime τ m in the macula was 259 ± 137 ps in the patients versus 147 ± 69 ps in the controls. A logistic regression model allowed discrimination between study and control group with a sensitivity of 90.09% and a specificity of 71.4% (area under the curve: 0.865). Significantly shorter τ m in the patients group than in the control group was detected in channel 2 in the crystalline lens (1587 ± 326 ps versus 1854 ± 384 ps, p = 0.006). Conclusions: Fundus Fluorescence lifetimes are significantly increased in NPDR while lens lifetimes are shorter in the patient group. Lifetime changes might be indicative for the accumulation of advanced glycation end products (AGEs) which enables detection of the disease with high sensitivity and specificity possibly bearing diagnostic merit. … (more)
- Is Part Of:
- Acta ophthalmologica. Volume 95:Issue 1(2017)
- Journal:
- Acta ophthalmologica
- Issue:
- Volume 95:Issue 1(2017)
- Issue Display:
- Volume 95, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 95
- Issue:
- 1
- Issue Sort Value:
- 2017-0095-0001-0000
- Page Start:
- 33
- Page End:
- 40
- Publication Date:
- 2016-08-13
- Subjects:
- advanced glycation end products -- diabetic retinopathy -- fluorescence lifetime -- functional imaging
Ophthalmology -- Periodicals
617.7005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1755-3768 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/aos.13174 ↗
- Languages:
- English
- ISSNs:
- 1755-375X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0641.750500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 645.xml