Comparison of 3.0T MRI with 3D LAVA sequence and digital subtraction angiography for the assessment of accessory hepatic veins in Budd‐Chiari syndrome. Issue 2 (8th July 2016)
- Record Type:
- Journal Article
- Title:
- Comparison of 3.0T MRI with 3D LAVA sequence and digital subtraction angiography for the assessment of accessory hepatic veins in Budd‐Chiari syndrome. Issue 2 (8th July 2016)
- Main Title:
- Comparison of 3.0T MRI with 3D LAVA sequence and digital subtraction angiography for the assessment of accessory hepatic veins in Budd‐Chiari syndrome
- Authors:
- Lu, Li
Xu, Kai
Han, Cuiping
Xu, Chao
Xu, Huiting
Dai, Yue
Rong, Yutao
Li, Shaodong
Xie, Lixiang - Abstract:
- Abstract : Purpose: To compare 3D liver acceleration volume acquisition (LAVA) and digital subtraction angiography (DSA) for evaluating the presence of accessory hepatic veins (AHV) in Budd‐Chiari syndrome (BCS). Materials and Methods: This was a retrospective study in 228 patients with BCS who underwent 3.0T magnetic resonance imaging (MRI) with the 3D LAVA sequence. Two reviewers noted AHV: openings located in the inferior vena cava (IVC), caliber, and the angle of entering into the IVC. MRI results were compared to DSA. Kappa statistics were calculated to quantify intrareader variability in detecting AHVs. Results: On MRI, 63 patients demonstrated no AHV on LAVA images, 70 had one AHV, 62 had two AHVs, 26 patients had three AHVs, six patients had four AHVs, and one patient had five AHVs ( P < 0.05 vs. DSA). The mean caliber of the AHVs was 8.3 ± 4.0 mm compared to 9.9 ± 3.2 for DSA ( P < 0.001). Among the 301 AHVs, there were 140 with acute angles (46.5%), 71 with right angles (23.6%), and 90 with obtuse angles (29.8%). The prevalence of AHVs on DSA was 54.8% (125/228), while MRI demonstrated 301 AHVs in 165 patients, for a prevalence of 72.4% (165/228) compared to 54.8% for DSA ( P = 0.001). The two methods were concordant in only 116/228 (50.9%) patients. The kappa coefficient demonstrated good intrareader consistency for all documented MRI findings of AHVs (κ = 0.626 for caliber and κ = 0.65 for angles). Conclusion: More AHVs were visible on MRI LAVA sequences than onAbstract : Purpose: To compare 3D liver acceleration volume acquisition (LAVA) and digital subtraction angiography (DSA) for evaluating the presence of accessory hepatic veins (AHV) in Budd‐Chiari syndrome (BCS). Materials and Methods: This was a retrospective study in 228 patients with BCS who underwent 3.0T magnetic resonance imaging (MRI) with the 3D LAVA sequence. Two reviewers noted AHV: openings located in the inferior vena cava (IVC), caliber, and the angle of entering into the IVC. MRI results were compared to DSA. Kappa statistics were calculated to quantify intrareader variability in detecting AHVs. Results: On MRI, 63 patients demonstrated no AHV on LAVA images, 70 had one AHV, 62 had two AHVs, 26 patients had three AHVs, six patients had four AHVs, and one patient had five AHVs ( P < 0.05 vs. DSA). The mean caliber of the AHVs was 8.3 ± 4.0 mm compared to 9.9 ± 3.2 for DSA ( P < 0.001). Among the 301 AHVs, there were 140 with acute angles (46.5%), 71 with right angles (23.6%), and 90 with obtuse angles (29.8%). The prevalence of AHVs on DSA was 54.8% (125/228), while MRI demonstrated 301 AHVs in 165 patients, for a prevalence of 72.4% (165/228) compared to 54.8% for DSA ( P = 0.001). The two methods were concordant in only 116/228 (50.9%) patients. The kappa coefficient demonstrated good intrareader consistency for all documented MRI findings of AHVs (κ = 0.626 for caliber and κ = 0.65 for angles). Conclusion: More AHVs were visible on MRI LAVA sequences than on conventional DSA. Level of Evidence: 4 J. Magn. Reson. Imaging 2017;45:401–409. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 45:Issue 2(2017)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 45:Issue 2(2017)
- Issue Display:
- Volume 45, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 45
- Issue:
- 2
- Issue Sort Value:
- 2017-0045-0002-0000
- Page Start:
- 401
- Page End:
- 409
- Publication Date:
- 2016-07-08
- Subjects:
- Budd‐Chiari syndrome -- accessory hepatic vein -- magnetic resonance imaging -- LAVA sequence -- digital subtraction angiography
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25381 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2306.xml