Development and application of a UHPLC‐MS/MS method for the simultaneous determination of 17 steroidal hormones in equine serum. (22nd November 2016)
- Record Type:
- Journal Article
- Title:
- Development and application of a UHPLC‐MS/MS method for the simultaneous determination of 17 steroidal hormones in equine serum. (22nd November 2016)
- Main Title:
- Development and application of a UHPLC‐MS/MS method for the simultaneous determination of 17 steroidal hormones in equine serum
- Authors:
- Genangeli, Michele
Caprioli, Giovanni
Cortese, Manuela
Laus, Fulvio
Matteucci, Mara
Petrelli, Riccardo
Ricciutelli, Massimo
Sagratini, Gianni
Sartori, Stefano
Vittori, Sauro - Abstract:
- Abstract : A new, fast and simple analytical method that is able to identify and quantify simultaneously 17 steroid hormones and metabolites (pregnenolone, 17‐OH‐pregnenolone, progesterone, 17‐OH‐progesterone, androsterone, androstenedione, dehydroepiandrosterone, dehydroepiandrosterone sulfate, testosterone, cortisol, corticosterone, aldosterone, 11‐deoxycortisol, 11‐deoxycorticosterone, dihydrotestosterone, estrone and estradiol) has been developed in equine serum using the ultra‐high‐performance liquid chromatography–tandem mass spectrometry technique. A total of 400 µl of sample was deproteinized with 1000 µl of acetonitrile, evaporated, restored with 50 µl of a solution of 25% methanol and injected in ultra‐high‐performance liquid chromatography–tandem mass spectrometry triple quadrupole. The recovery percentage obtained by spiking the matrix at two different concentrations with a standard mixture of steroid hormones was in all cases higher than 85.60% and with the percentage of coefficient of variation lower than 8.37%. The range of the correlation coefficients of the calibration curves of the analyzed compounds was 0.9922–0.9986, and the limits of detection and limits of quantification were in the range of 0.002–2 and 0.0055–5.5 ng ml −1, respectively. The detected limit of quantification for testosterone (i.e. 50 pg ml −1 ) is twofold lower with respect to its threshold admitted in geldings plasma (100 pg ml −1 free testosterone). The high sensitivity and theAbstract : A new, fast and simple analytical method that is able to identify and quantify simultaneously 17 steroid hormones and metabolites (pregnenolone, 17‐OH‐pregnenolone, progesterone, 17‐OH‐progesterone, androsterone, androstenedione, dehydroepiandrosterone, dehydroepiandrosterone sulfate, testosterone, cortisol, corticosterone, aldosterone, 11‐deoxycortisol, 11‐deoxycorticosterone, dihydrotestosterone, estrone and estradiol) has been developed in equine serum using the ultra‐high‐performance liquid chromatography–tandem mass spectrometry technique. A total of 400 µl of sample was deproteinized with 1000 µl of acetonitrile, evaporated, restored with 50 µl of a solution of 25% methanol and injected in ultra‐high‐performance liquid chromatography–tandem mass spectrometry triple quadrupole. The recovery percentage obtained by spiking the matrix at two different concentrations with a standard mixture of steroid hormones was in all cases higher than 85.60% and with the percentage of coefficient of variation lower than 8.37%. The range of the correlation coefficients of the calibration curves of the analyzed compounds was 0.9922–0.9986, and the limits of detection and limits of quantification were in the range of 0.002–2 and 0.0055–5.5 ng ml −1, respectively. The detected limit of quantification for testosterone (i.e. 50 pg ml −1 ) is twofold lower with respect to its threshold admitted in geldings plasma (100 pg ml −1 free testosterone). The high sensitivity and the quantitative aspect of the method permitted to detect most of the steroids in equine serum. Once validated, the method was used to quantify 17 steroid hormones in mare, stallion and gelding serum samples. The main steroids detected were corticosterone (range 37.25–51.26 ng ml −1 ) and cortisol (range 32.57–52.24 ng ml −1 ), followed by 17‐OH‐pregnenolone, dihydrotestosterone and pregnenolone. Copyright © 2016 John Wiley & Sons, Ltd. … (more)
- Is Part Of:
- Journal of mass spectrometry. Volume 52:Number 1(2017)
- Journal:
- Journal of mass spectrometry
- Issue:
- Volume 52:Number 1(2017)
- Issue Display:
- Volume 52, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 52
- Issue:
- 1
- Issue Sort Value:
- 2017-0052-0001-0000
- Page Start:
- 22
- Page End:
- 29
- Publication Date:
- 2016-11-22
- Subjects:
- UHPLC‐MS/MS -- steroidal hormones -- equine serum -- hormones -- validation
Mass spectrometry -- Periodicals
543.65 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jms.3896 ↗
- Languages:
- English
- ISSNs:
- 1076-5174
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5012.179500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File: