Quantification of 1‐(propan‐2‐ylamino)‐4‐propoxy‐9H‐thioxanthen‐9‐one (TX5), a newly synthetized P‐glycoprotein inducer/activator, in biological samples: method development and validation. (21st September 2016)
- Record Type:
- Journal Article
- Title:
- Quantification of 1‐(propan‐2‐ylamino)‐4‐propoxy‐9H‐thioxanthen‐9‐one (TX5), a newly synthetized P‐glycoprotein inducer/activator, in biological samples: method development and validation. (21st September 2016)
- Main Title:
- Quantification of 1‐(propan‐2‐ylamino)‐4‐propoxy‐9H‐thioxanthen‐9‐one (TX5), a newly synthetized P‐glycoprotein inducer/activator, in biological samples: method development and validation
- Authors:
- Ferreira, Ana Filipa
Ponte, Filipa
Silva, Renata
Rocha‐Pereira, Carolina
Sousa, Emília
Pinto, Madalena
Bastos, Maria de Lourdes
Remião, Fernando - Abstract:
- Abstract: A simple, rapid and economical method was developed and validated for the analysis and quantification of 1‐(propan‐2‐ylamino)‐4‐propoxy‐9 H ‐thioxanthen‐9‐one (TX5), a P‐glycoprotein inducer/activator, in biological samples, using reverse‐phase high‐performance liquid chromatography (HPLC). A C18 column and a mobile phase composed of methanol–water (90/10, v /v) with 1% (v/v) triethylamine, at a flow rate of 1 mL/min, were used for chromatographic separation. TX5 standards (0.5–150 μm ) were prepared in human serum. Methanol was used for TX5 extraction and serum protein precipitation. After filtration, samples were injected into the HPLC apparatus and TX5 was quantified by a conventional UV detector at 255 nm. The TX5 retention time was 13 min in this isocratic system. The method was validated according to ICH guidelines for specificity/selectivity, linearity, accuracy, precision, limits of detection and quantification (LOD and LOQ) and recovery. The method was proved to be selective, as there were no interferences of endogenous compounds with the same retention time of TX5. Also, the developed method was linear ( r 2 ≥ 0.99) for TX5 concentrations between 0.5 and 150 μm and the LOD and LOQ were 0.08 and 0.23 μm, respectively. The results indicated that the reported method could meet the requirements for TX5 analysis in the trace amounts expected to be present in biological samples.
- Is Part Of:
- Biomedical chromatography. Volume 31:Number 2(2017:Feb.)
- Journal:
- Biomedical chromatography
- Issue:
- Volume 31:Number 2(2017:Feb.)
- Issue Display:
- Volume 31, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 31
- Issue:
- 2
- Issue Sort Value:
- 2017-0031-0002-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2016-09-21
- Subjects:
- activation -- HPLC -- induction -- method validation -- P‐glycoprotein -- thioxanthones
Chromatographic analysis -- Periodicals
Biology -- Periodicals
Medicine -- Periodicals
Biology -- Periodicals
Chromatography -- methods -- Periodicals
Medicine -- Periodicals
543.089 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/bmc.3802 ↗
- Languages:
- English
- ISSNs:
- 0269-3879
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.758000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1050.xml