Canadian Registry of Implantable Electronic Device Outcomes: Surveillance of the Riata Lead Under Advisory. (October 2016)
- Record Type:
- Journal Article
- Title:
- Canadian Registry of Implantable Electronic Device Outcomes: Surveillance of the Riata Lead Under Advisory. (October 2016)
- Main Title:
- Canadian Registry of Implantable Electronic Device Outcomes
- Authors:
- Parkash, Ratika
Thibault, Bernard
Mangat, Iqwal
Coutu, Benoit
Bennett, Matthew
Healey, Jeffrey
Verma, Atul
Philippon, Francois
Sandhu, Roopinder
Cameron, Douglas
Ayala-Paredes, Felix
Sterns, Laurence
Essebag, Vidal
Kus, Teresa
Nery, Pablo
Stephenson, Elizabeth
Yee, Raymond
Exner, Derek
Toal, Satish
Birnie, David
Wells, George
Krahn, Andrew - Abstract:
- Abstract : Background—: The Riata lead under advisory has posed a unique clinical scenario where inside-out abrasion results in externalization of conductor cables, with a higher risk of electrical failure. We developed a comprehensive registry to assist with clinical management of this lead. Methods and Results—: This Canadian registry reports the findings of 3763 (74.2% of all Riata leads in Canada) Riata leads under advisory, with a mean follow-up time of 8.9±1.5 years. The overall electrical failure rate was 5.2% at 8 years, with no difference between 7-French and 8-French lead models. Cable externalization was found to be more common in the 8-French model (12.3% versus 5.2%, P <0.0001) and was associated with a higher risk of electrical failure. Predictors of electrical lead failure included cable externalization, higher left ventricular ejection fraction, younger age, higher body mass index, and a passive fixation lead. One patient died due to electrical failure, a further 2 patients survived an event where the device failed to deliver high-voltage therapy. Major complications because of lead extraction were higher when compared with lead abandonment, no difference among lead model observed. Two deaths occurred as a consequence of lead extraction, in the context of an underlying infection. Conclusions—: The Riata lead under advisory has a steady electrical failure rate over time. There are identifiable predictors of lead failure that can assist with clinical decisionsAbstract : Background—: The Riata lead under advisory has posed a unique clinical scenario where inside-out abrasion results in externalization of conductor cables, with a higher risk of electrical failure. We developed a comprehensive registry to assist with clinical management of this lead. Methods and Results—: This Canadian registry reports the findings of 3763 (74.2% of all Riata leads in Canada) Riata leads under advisory, with a mean follow-up time of 8.9±1.5 years. The overall electrical failure rate was 5.2% at 8 years, with no difference between 7-French and 8-French lead models. Cable externalization was found to be more common in the 8-French model (12.3% versus 5.2%, P <0.0001) and was associated with a higher risk of electrical failure. Predictors of electrical lead failure included cable externalization, higher left ventricular ejection fraction, younger age, higher body mass index, and a passive fixation lead. One patient died due to electrical failure, a further 2 patients survived an event where the device failed to deliver high-voltage therapy. Major complications because of lead extraction were higher when compared with lead abandonment, no difference among lead model observed. Two deaths occurred as a consequence of lead extraction, in the context of an underlying infection. Conclusions—: The Riata lead under advisory has a steady electrical failure rate over time. There are identifiable predictors of lead failure that can assist with clinical decisions as to whether lead revision should be performed prophylactically. … (more)
- Is Part Of:
- Circulation. Volume 9:Number 10(2016)
- Journal:
- Circulation
- Issue:
- Volume 9:Number 10(2016)
- Issue Display:
- Volume 9, Issue 10 (2016)
- Year:
- 2016
- Volume:
- 9
- Issue:
- 10
- Issue Sort Value:
- 2016-0009-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-10
- Subjects:
- catheter ablation -- complications -- electrophysiology -- heart failure -- implantable cardioverter-defibrillator
Arrhythmia -- Periodicals
Heart -- Electric properties -- Periodicals
616.128 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01337493-000000000-00000 ↗
http://circep.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCEP.116.004282 ↗
- Languages:
- English
- ISSNs:
- 1941-3149
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1314.xml