Assessment of increased sampling pump flow rates in a disposable, inhalable aerosol sampler. Issue 3 (4th March 2017)
- Record Type:
- Journal Article
- Title:
- Assessment of increased sampling pump flow rates in a disposable, inhalable aerosol sampler. Issue 3 (4th March 2017)
- Main Title:
- Assessment of increased sampling pump flow rates in a disposable, inhalable aerosol sampler
- Authors:
- Stewart, Justin
Sleeth, Darrah K.
Handy, Rod G.
Pahler, Leon F.
Anthony, T. Renee
Volckens, John - Abstract:
- ABSTRACT: A newly designed, low-cost, disposable inhalable aerosol sampler was developed to assess workers personal exposure to inhalable particles. This sampler was originally designed to operate at 10 L/min to increase sample mass and, therefore, improve analytical detection limits for filter-based methods. Computational fluid dynamics modeling revealed that sampler performance (relative to aerosol inhalability criteria) would not differ substantially at sampler flows of 2 and 10 L/min. With this in mind, the newly designed inhalable aerosol sampler was tested in a wind tunnel, simultaneously, at flows of 2 and 10 L/min flow. A mannequin was equipped with 6 sampler/pump assemblies (three pumps operated at 2 L/min and three pumps at 10 L/min) inside a wind tunnel, operated at 0.2 m/s, which has been shown to be a typical indoor workplace wind speed. In separate tests, four different particle sizes were injected to determine if the sampler's performance with the new 10 L/min flow rate significantly differed to that at 2 L/min. A comparison between inhalable mass concentrations using a Wilcoxon signed rank test found no significant difference in the concentration of particles sampled at 10 and 2 L/min for all particle sizes tested. Our results suggest that this new aerosol sampler is a versatile tool that can improve exposure assessment capabilities for the practicing industrial hygienist by improving the limit of detection and allowing for shorting sampling times.
- Is Part Of:
- Journal of occupational and environmental hygiene. Volume 14:Issue 3(2017)
- Journal:
- Journal of occupational and environmental hygiene
- Issue:
- Volume 14:Issue 3(2017)
- Issue Display:
- Volume 14, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 14
- Issue:
- 3
- Issue Sort Value:
- 2017-0014-0003-0000
- Page Start:
- 207
- Page End:
- 213
- Publication Date:
- 2017-03-04
- Subjects:
- Aerosols -- exposure assessment -- high-flow -- inhalable sampler -- wind tunnel
Industrial hygiene -- Periodicals
Environmental health -- Periodicals
Medicine, Industrial -- Periodicals
Occupational Health -- Periodicals
Environmental Exposure -- Periodicals
Environmental Health -- Periodicals
Occupational Exposure -- Periodicals
Hygiène industrielle -- Périodiques
Hygiène du milieu -- Périodiques
Médecine du travail -- Périodiques
613.62 - Journal URLs:
- http://www.tandfonline.com/ ↗
- DOI:
- 10.1080/15459624.2016.1237028 ↗
- Languages:
- English
- ISSNs:
- 1545-9624
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5026.080500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 371.xml