Association Between a Prolonged PR Interval and Outcomes of Cardiac Resynchronization Therapy: A Report From the National Cardiovascular Data Registry. Issue 21 (22nd November 2016)
- Record Type:
- Journal Article
- Title:
- Association Between a Prolonged PR Interval and Outcomes of Cardiac Resynchronization Therapy: A Report From the National Cardiovascular Data Registry. Issue 21 (22nd November 2016)
- Main Title:
- Association Between a Prolonged PR Interval and Outcomes of Cardiac Resynchronization Therapy
- Authors:
- Friedman, Daniel J.
Bao, Haikun
Spatz, Erica S.
Curtis, Jeptha P.
Daubert, James P.
Al-Khatib, Sana M. - Abstract:
- Abstract : Background: A prolonged PR interval is common among cardiac resynchronization therapy (CRT) candidates; however, the association between PR interval and outcomes is unclear, and the data are conflicting. Methods: We conducted inverse probability weighted analyses of 26 451 CRT-eligible (ejection fraction ⩽35, QRS ≥120 ms) patients from the National Cardiovascular Data Registry ICD Registry to assess the association between a prolonged PR interval (≥230 ms), receipt of CRT with defibrillator (CRT-D) versus implantable cardioverter defibrillator (ICD), and outcomes. We first tested the association between a prolonged PR interval and outcomes among patients stratified by device type. Next, we performed a comparative effectiveness analysis of CRT-D versus ICD among patients when stratified by PR interval. Using Medicare claims data, we followed up with patients up to 5 years for incident heart failure hospitalization or death. Results: Patients with a PR≥230 ms (15%; n=4035) were older and had more comorbidities, including coronary artery disease, atrial arrhythmias, diabetes mellitus, and chronic kidney disease. After risk adjustment, a PR≥230 ms (versus PR<230 ms) was associated with increased risk of heart failure hospitalization or death among CRT-D (hazard ratio, 1.23; 95% confidence interval, 1.14–1.31; P <0.001) but not ICD recipients (hazard ratio, 1.08; 95% confidence interval, 0.97–1.20; P =0.17) ( P interaction =0.043). CRT-D (versus ICD) was associatedAbstract : Background: A prolonged PR interval is common among cardiac resynchronization therapy (CRT) candidates; however, the association between PR interval and outcomes is unclear, and the data are conflicting. Methods: We conducted inverse probability weighted analyses of 26 451 CRT-eligible (ejection fraction ⩽35, QRS ≥120 ms) patients from the National Cardiovascular Data Registry ICD Registry to assess the association between a prolonged PR interval (≥230 ms), receipt of CRT with defibrillator (CRT-D) versus implantable cardioverter defibrillator (ICD), and outcomes. We first tested the association between a prolonged PR interval and outcomes among patients stratified by device type. Next, we performed a comparative effectiveness analysis of CRT-D versus ICD among patients when stratified by PR interval. Using Medicare claims data, we followed up with patients up to 5 years for incident heart failure hospitalization or death. Results: Patients with a PR≥230 ms (15%; n=4035) were older and had more comorbidities, including coronary artery disease, atrial arrhythmias, diabetes mellitus, and chronic kidney disease. After risk adjustment, a PR≥230 ms (versus PR<230 ms) was associated with increased risk of heart failure hospitalization or death among CRT-D (hazard ratio, 1.23; 95% confidence interval, 1.14–1.31; P <0.001) but not ICD recipients (hazard ratio, 1.08; 95% confidence interval, 0.97–1.20; P =0.17) ( P interaction =0.043). CRT-D (versus ICD) was associated with lower rates of heart failure hospitalization or death among patients with PR<230 ms (hazard ratio, 0.79; 95% confidence interval, 0.73–0.85; P <0.001) but not PR≥230 ms (hazard ratio, 1.01; 95% confidence interval, 0.87–1.17; P =0.90) ( P interaction =0.0025). Conclusions: A PR≥230 ms is associated with increased rates of heart failure hospitalization or death among CRT-D patients. The real-world comparative effectiveness of CRT-D (versus ICD) is significantly less among patients with a PR≥230 ms in comparison with patients with a PR<230 ms. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 134:Issue 21(2016)
- Journal:
- Circulation
- Issue:
- Volume 134:Issue 21(2016)
- Issue Display:
- Volume 134, Issue 21 (2016)
- Year:
- 2016
- Volume:
- 134
- Issue:
- 21
- Issue Sort Value:
- 2016-0134-0021-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-11-22
- Subjects:
- atrioventricular block -- cardiac resynchronization therapy -- cardiomyopathies -- defibrillators -- pacemaker, artificial
Blood -- Circulation -- Periodicals
Cardiovascular system -- Periodicals
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
Blood Circulation
Cardiovascular System
Vascular Diseases
616.1 - Journal URLs:
- http://ovidsp.tx.ovid.com/sp-3.4.2a/ovidweb.cgi?&S=HFFJFPCLPODDKOLGNCALDCMCIACKAA00&Browse=Toc+Children%7cNO%7cS.sh.1384_1326796138_84.1384_1326796138_96.1384_1326796138_97%7c66%7c50 ↗
http://www.circulationaha.org ↗
http://circ.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCULATIONAHA.116.022913 ↗
- Languages:
- English
- ISSNs:
- 0009-7322
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2808.xml