Echocardiographic and Surgical Correlation of Coronary Artery Patterns in Transposition of the Great Arteries1. (2nd March 2016)
- Record Type:
- Journal Article
- Title:
- Echocardiographic and Surgical Correlation of Coronary Artery Patterns in Transposition of the Great Arteries1. (2nd March 2016)
- Main Title:
- Echocardiographic and Surgical Correlation of Coronary Artery Patterns in Transposition of the Great Arteries1
- Authors:
- Fundora, Michael P.
Aregullin, Enrique Oliver
Wernovsky, Gil
Welch, Elizabeth M.
Muniz, Juan‐Carlos
Sasaki, Nao
Hannan, Robert L.
Burke, Redmond P.
Lopez, Leo - Abstract:
- Abstract: Objective: Determine the accuracy of echocardiography to diagnose coronary anatomy in transposition of the great arteries and to evaluate the effect of accuracy on surgical outcomes and changes in accuracy over time. Design: Retrospective chart review of neonates admitted February 1999 to March 2013 with transposition. Coronary pattern from the preoperative echocardiogram and operative reports were collected and compared with determine diagnostic accuracy. Coronary patterns were further confirmed by intraoperative images taken during surgery. Setting: Tertiary care children's hospital. Patients: Neonates with transposition of the great arteries and planned arterial switch operation with an echo and operative report or image describing the coronaries. Interventions: Not applicable. Outcome Measures: Accuracy of echocardiography to diagnose coronary anatomy in transposition, and to identify factors related to correct diagnosis. Results: One hundred forty‐two patients met inclusion criteria with 122 correctly diagnosed, 16 incorrect, and 4 inconclusive. Accuracy was 86%, with 95% accuracy in patients with typical coronary patterns, 85% with the most common variant (left coronary from the leftward sinus and right and circumflex from the rightward sinus), and 61% with less common patterns. Typical and common variants were more likely to be correct than atypical patterns ( P < .001). Cases with ventricular septal defect were more likely to have correctly diagnosedAbstract: Objective: Determine the accuracy of echocardiography to diagnose coronary anatomy in transposition of the great arteries and to evaluate the effect of accuracy on surgical outcomes and changes in accuracy over time. Design: Retrospective chart review of neonates admitted February 1999 to March 2013 with transposition. Coronary pattern from the preoperative echocardiogram and operative reports were collected and compared with determine diagnostic accuracy. Coronary patterns were further confirmed by intraoperative images taken during surgery. Setting: Tertiary care children's hospital. Patients: Neonates with transposition of the great arteries and planned arterial switch operation with an echo and operative report or image describing the coronaries. Interventions: Not applicable. Outcome Measures: Accuracy of echocardiography to diagnose coronary anatomy in transposition, and to identify factors related to correct diagnosis. Results: One hundred forty‐two patients met inclusion criteria with 122 correctly diagnosed, 16 incorrect, and 4 inconclusive. Accuracy was 86%, with 95% accuracy in patients with typical coronary patterns, 85% with the most common variant (left coronary from the leftward sinus and right and circumflex from the rightward sinus), and 61% with less common patterns. Typical and common variants were more likely to be correct than atypical patterns ( P < .001). Cases with ventricular septal defect were more likely to have correctly diagnosed coronaries than with an intact ventricular septum (94% vs. 79%, P = .01). There was no change in accuracy over time ( P > .05). There was no difference in duration of cardiopulmonary bypass, cross‐clamp times, length of stay, or postoperative stay between the correct and incorrectly diagnosed groups ( P > .05). Conclusions: In our center, accuracy of echocardiographic imaging of the coronary arteries in transposition was 86% without improvement over time, and perioperative outcomes were not affected by diagnostic accuracy. Further invasive imaging may not be necessary to determine the coronary pattern in this lesion. … (more)
- Is Part Of:
- Congenital heart disease. Volume 11:Number 6(2016)
- Journal:
- Congenital heart disease
- Issue:
- Volume 11:Number 6(2016)
- Issue Display:
- Volume 11, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 11
- Issue:
- 6
- Issue Sort Value:
- 2016-0011-0006-0000
- Page Start:
- 570
- Page End:
- 577
- Publication Date:
- 2016-03-02
- Subjects:
- Transposition of the Great Arteries -- Arterial Switch Operation -- Coronary Arteries -- Outcomes -- Echocardiography
Congenital heart disease -- Periodicals
616.1204305 - Journal URLs:
- https://www.techscience.com/journal/chd ↗
http://firstsearch.oclc.org ↗
http://proxy.library.carleton.ca/login?url=http://www3.interscience.wiley.com/cgi-bin/issn?DESCRIPTOR=PRINTISSN&VALUE=1747-079X ↗
http://onlinelibrary.wiley.com/ ↗
http://www.blackwell-synergy.com/loi/chd ↗
http://www.blackwell-synergy.com/toc/chd/1/3;jsessionid=bBP_cvinxU9dsOWrNX ↗ - DOI:
- 10.1111/chd.12338 ↗
- Languages:
- English
- ISSNs:
- 1747-079X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3410.683800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1085.xml