Comparison of physiological and post-endovascular aneurysm repair infrarenal blood flow. Issue 3 (17th February 2017)
- Record Type:
- Journal Article
- Title:
- Comparison of physiological and post-endovascular aneurysm repair infrarenal blood flow. Issue 3 (17th February 2017)
- Main Title:
- Comparison of physiological and post-endovascular aneurysm repair infrarenal blood flow
- Authors:
- Raptis, Anastasios
Xenos, Michalis
Georgakarakos, Efstratios
Kouvelos, George
Giannoukas, Athanasios
Labropoulos, Nicos
Matsagkas, Miltiadis - Abstract:
- Abstract: Endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms results in redirection of blood through the deployed endograft (EG). Even though EVAR is clinically effective, the absolute flow restoration is not warranted. Our purpose was to compare the physiological with the post-EVAR infrarenal flow conditions. We developed patient-specific models based on computed tomography data of five healthy volunteers and ten patients treated with the Endurant ® stent-graft system. Wall shear stress (WSS), helicity, pressure and velocity fields were calculated using computational fluid dynamics. The results showed a decrease of peak WSS on the part of the EG that resides in the iliac arteries, compared to the physiological value ( p = 0.01). At the abdominal part, the average helicity seems to increase after EVAR, while at the iliac arteries part, the intensity of helical flow seems physiological. Pressure drop and peak velocity in the iliac arteries part are lower than the physiological values ( p = 0.04). The comparison revealed that most hemodynamic properties converge to normal levels at the abdominal part whereas statistically significant variations were observed in the iliac arteries part. The delineation of the differences between physiological and postoperative flow data could pave the way for the improvement of EG designs.
- Is Part Of:
- Computer methods in biomechanics and biomedical engineering. Volume 20:Issue 3(2017)
- Journal:
- Computer methods in biomechanics and biomedical engineering
- Issue:
- Volume 20:Issue 3(2017)
- Issue Display:
- Volume 20, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 20
- Issue:
- 3
- Issue Sort Value:
- 2017-0020-0003-0000
- Page Start:
- 242
- Page End:
- 249
- Publication Date:
- 2017-02-17
- Subjects:
- Endovascular aneurysm repair -- endograft -- hemodynamics -- comparison
Biomechanics -- Data processing -- Periodicals
Biomedical engineering -- Periodicals
Biomechanics -- Periodicals
Biomedical Engineering -- methods -- Periodicals
Computing Methodologies -- Periodicals
612.7 - Journal URLs:
- http://www.tandfonline.com/toc/gcmb20/current ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/10255842.2016.1215437 ↗
- Languages:
- English
- ISSNs:
- 1025-5842
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.100250
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2588.xml