Assessing daylight luminance values and daylight glare probability in scale models. (15th February 2017)
- Record Type:
- Journal Article
- Title:
- Assessing daylight luminance values and daylight glare probability in scale models. (15th February 2017)
- Main Title:
- Assessing daylight luminance values and daylight glare probability in scale models
- Authors:
- Bodart, M.
Cauwerts, C. - Abstract:
- Abstract: This paper presents a research about the possibility to use a scale model of a room to assess the luminances in the visual field of the room's user, and consequently its risk of glare. Measurements of luminance values by the HDR technique were done simultaneously in a room and its 1/6 scale model, with identical measurement material. The room was lit by a lateral window either unprotected from direct sun radiation, or fitted with a white or black screen. Measurements show that luminance values obtained in the scale model are overestimated and that the relative differences between values in the scale model and in the mock-up vary between 10 and 50% for the situation without shading device, between 45 and 80% for the window equipped with the white screen and between 0 and 45% with the black screen. Yet, the evolution of luminances is very similar for both rooms, and a high level of correlation is observed between glare index DGP values calculated on these respective luminance values, despite a very slight over-evaluation of the DGP in the scale model. In conclusion, for the situation tested, the DGP can be evaluated using a 1:6 scale model, under the condition of very accurately respecting the geometry and photometric data of the studied room walls. It is also very important to position the scale model in a way to obtain a view on the outside as similar as possible to the one obtained from the studied room. Highlights: Comparison of luminance values and DGP measuredAbstract: This paper presents a research about the possibility to use a scale model of a room to assess the luminances in the visual field of the room's user, and consequently its risk of glare. Measurements of luminance values by the HDR technique were done simultaneously in a room and its 1/6 scale model, with identical measurement material. The room was lit by a lateral window either unprotected from direct sun radiation, or fitted with a white or black screen. Measurements show that luminance values obtained in the scale model are overestimated and that the relative differences between values in the scale model and in the mock-up vary between 10 and 50% for the situation without shading device, between 45 and 80% for the window equipped with the white screen and between 0 and 45% with the black screen. Yet, the evolution of luminances is very similar for both rooms, and a high level of correlation is observed between glare index DGP values calculated on these respective luminance values, despite a very slight over-evaluation of the DGP in the scale model. In conclusion, for the situation tested, the DGP can be evaluated using a 1:6 scale model, under the condition of very accurately respecting the geometry and photometric data of the studied room walls. It is also very important to position the scale model in a way to obtain a view on the outside as similar as possible to the one obtained from the studied room. Highlights: Comparison of luminance values and DGP measured in a room and its 1/6 scale-model. High overestimation of luminance values in the scale-model. Low overestimation of DGP in the scale model and high correlation. A 1/6 scale-model can be used to evaluate DGP. These results should be validated for other geometrical cases. … (more)
- Is Part Of:
- Building and environment. Volume 113(2017)
- Journal:
- Building and environment
- Issue:
- Volume 113(2017)
- Issue Display:
- Volume 113, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 113
- Issue:
- 2017
- Issue Sort Value:
- 2017-0113-2017-0000
- Page Start:
- 210
- Page End:
- 219
- Publication Date:
- 2017-02-15
- Subjects:
- Daylighting -- Visual comfort -- Luminance -- Scale models
Buildings -- Environmental engineering -- Periodicals
Building -- Research -- Periodicals
Constructions -- Technique de l'environnement -- Périodiques
Electronic journals
696 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03601323 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.buildenv.2016.08.033 ↗
- Languages:
- English
- ISSNs:
- 0360-1323
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2359.355000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2561.xml