Electrochemical behavior of the cotinine at a boron-doped diamond electrode and its determination in saliva by multiple-pulse amperometry in an FIA system. (20th December 2016)
- Record Type:
- Journal Article
- Title:
- Electrochemical behavior of the cotinine at a boron-doped diamond electrode and its determination in saliva by multiple-pulse amperometry in an FIA system. (20th December 2016)
- Main Title:
- Electrochemical behavior of the cotinine at a boron-doped diamond electrode and its determination in saliva by multiple-pulse amperometry in an FIA system
- Authors:
- Alecrim, Morgana F.
Oliveira, Fernando M.
Guedes, Tiago J.
Neves, Camila D.c.
Mendonça, Vanessa A.
Gil, Eric S.
Verly, Rodrigo M.
dos Santos, Wallans T.P. - Abstract:
- Abstract: Cotinine (CO) is the principal metabolite of nicotine, and it is used as a biomarker to monitor the exposure of an individual to tobacco. This paper sought to present the use of a boron-doped diamond (BDD) electrode for the electrochemical characterization of CO by voltammetric techniques and its quantification in saliva samples by multiple-pulse amperometry (MPA) in a flow injection analysis (FIA) system. In phosphate buffer solution 0.1 mol L −1 (pH 7), the CO presented two electrochemical processes, one anodic at +1.8 V and one cathodic at −1.2 V (vs. Ag/AgCl). The second process was dependent on the first and both processes were irreversible. It was found that CO electrochemical processes are controlled by diffusion and that two-protons and two-electrons are involved in the oxidation reaction. In determination of CO in saliva samples, the MPA detection was used, applying four potential pulses: (1) at +1.8 V/400 ms, generator potential pulse for oxidation of CO; (2) at −1.0 V/500 ms, potential pulse for remove possible interferents; (3) at −1.2 V/30 ms, collector potential pulse for reduction of the product generated and CO quantification; (4) 1.45 V/300 ms, potential pulse for cleaning BDD electrode. The proposed method attained an analytical frequency of 36 determinations per hour with a relative standard deviation of 1.47% for 10 measurements of 1.0 × 10 −5 mol L −1 CO. A good linear range from 0.5 to 100 μmol L −1 was obtained with a detection limit for COAbstract: Cotinine (CO) is the principal metabolite of nicotine, and it is used as a biomarker to monitor the exposure of an individual to tobacco. This paper sought to present the use of a boron-doped diamond (BDD) electrode for the electrochemical characterization of CO by voltammetric techniques and its quantification in saliva samples by multiple-pulse amperometry (MPA) in a flow injection analysis (FIA) system. In phosphate buffer solution 0.1 mol L −1 (pH 7), the CO presented two electrochemical processes, one anodic at +1.8 V and one cathodic at −1.2 V (vs. Ag/AgCl). The second process was dependent on the first and both processes were irreversible. It was found that CO electrochemical processes are controlled by diffusion and that two-protons and two-electrons are involved in the oxidation reaction. In determination of CO in saliva samples, the MPA detection was used, applying four potential pulses: (1) at +1.8 V/400 ms, generator potential pulse for oxidation of CO; (2) at −1.0 V/500 ms, potential pulse for remove possible interferents; (3) at −1.2 V/30 ms, collector potential pulse for reduction of the product generated and CO quantification; (4) 1.45 V/300 ms, potential pulse for cleaning BDD electrode. The proposed method attained an analytical frequency of 36 determinations per hour with a relative standard deviation of 1.47% for 10 measurements of 1.0 × 10 −5 mol L −1 CO. A good linear range from 0.5 to 100 μmol L −1 was obtained with a detection limit for CO estimated at 0.06 μmol L −1 . Approximately 100% of the CO added to saliva samples was recovered. Therefore, this work presents, for the first time, the electrochemical behavior of the CO at an electrode as well as a simple, fast and low-cost method for monitoring the degree of exposure to tobacco by CO determination in saliva samples using the FIA-MPA technique. … (more)
- Is Part Of:
- Electrochimica acta. Volume 222(2016)
- Journal:
- Electrochimica acta
- Issue:
- Volume 222(2016)
- Issue Display:
- Volume 222, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 222
- Issue:
- 2016
- Issue Sort Value:
- 2016-0222-2016-0000
- Page Start:
- 331
- Page End:
- 337
- Publication Date:
- 2016-12-20
- Subjects:
- Cotinine -- Tobacco -- Pulsed Amperometry -- FIA -- Boron-Doped Diamond
Electrochemistry -- Periodicals
Electrochemistry, Industrial -- Periodicals
541.37 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00134686 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.electacta.2016.10.177 ↗
- Languages:
- English
- ISSNs:
- 0013-4686
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3698.950000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2277.xml