Incorporation of gradient vector flow field in a multimodal graph-theoretic approach for segmenting the internal limiting membrane from glaucomatous optic nerve head-centered SD-OCT volumes. (January 2017)
- Record Type:
- Journal Article
- Title:
- Incorporation of gradient vector flow field in a multimodal graph-theoretic approach for segmenting the internal limiting membrane from glaucomatous optic nerve head-centered SD-OCT volumes. (January 2017)
- Main Title:
- Incorporation of gradient vector flow field in a multimodal graph-theoretic approach for segmenting the internal limiting membrane from glaucomatous optic nerve head-centered SD-OCT volumes
- Authors:
- Miri, Mohammad Saleh
Robles, Victor A.
Abràmoff, Michael D.
Kwon, Young H.
Garvin, Mona K. - Abstract:
- Abstract : Highlights: We present a multimodal approach for segmenting the surface of the optic nerve head. A graph-based approach is extended to utilize gradient-vector-flow-based columns. Issues related to the presence of blood vessels and deep cups are overcome. The approach will enable more accurate computation of glaucomatous measures. Abstract: The internal limiting membrane (ILM) separates the retina and optic nerve head (ONH) from the vitreous. In the optical coherence tomography volumes of glaucoma patients, while current approaches for the segmentation of the ILM in the peripapillary and macular regions are considered robust, current approaches commonly produce ILM segmentation errors at the ONH due to the presence of blood vessels and/or characteristic glaucomatous deep cupping. Because a precise segmentation of the ILM surface at the ONH is required for computing several newer structural measurements including Bruch's membrane opening-minimum rim width (BMO-MRW) and cup volume, in this study, we propose a multimodal multiresolution graph-based method to precisely segment the ILM surface within ONH-centered spectral-domain optical coherence tomography (SD-OCT) volumes. In particular, the gradient vector flow (GVF) field, which is computed from a multiresolution initial segmentation, is employed for calculating a set of non-overlapping GVF-based columns perpendicular to the initial segmentation. The GVF columns are utilized to resample the volume and also serve asAbstract : Highlights: We present a multimodal approach for segmenting the surface of the optic nerve head. A graph-based approach is extended to utilize gradient-vector-flow-based columns. Issues related to the presence of blood vessels and deep cups are overcome. The approach will enable more accurate computation of glaucomatous measures. Abstract: The internal limiting membrane (ILM) separates the retina and optic nerve head (ONH) from the vitreous. In the optical coherence tomography volumes of glaucoma patients, while current approaches for the segmentation of the ILM in the peripapillary and macular regions are considered robust, current approaches commonly produce ILM segmentation errors at the ONH due to the presence of blood vessels and/or characteristic glaucomatous deep cupping. Because a precise segmentation of the ILM surface at the ONH is required for computing several newer structural measurements including Bruch's membrane opening-minimum rim width (BMO-MRW) and cup volume, in this study, we propose a multimodal multiresolution graph-based method to precisely segment the ILM surface within ONH-centered spectral-domain optical coherence tomography (SD-OCT) volumes. In particular, the gradient vector flow (GVF) field, which is computed from a multiresolution initial segmentation, is employed for calculating a set of non-overlapping GVF-based columns perpendicular to the initial segmentation. The GVF columns are utilized to resample the volume and also serve as the columns to the graph construction. The ILM surface in the resampled volume is fairly smooth and does not contain the steep slopes. This prior shape knowledge along with the blood vessel information, obtained from registered fundus photographs, are incorporated in a graph-theoretic approach in order to identify the location of the ILM surface. The proposed method is tested on the SD-OCT volumes of 44 subjects with various stages of glaucoma and significantly smaller segmentation errors were obtained than that of current approaches. … (more)
- Is Part Of:
- Computerized medical imaging and graphics. Volume 55(2017)
- Journal:
- Computerized medical imaging and graphics
- Issue:
- Volume 55(2017)
- Issue Display:
- Volume 55, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 55
- Issue:
- 2017
- Issue Sort Value:
- 2017-0055-2017-0000
- Page Start:
- 87
- Page End:
- 94
- Publication Date:
- 2017-01
- Subjects:
- SD-OCT -- Fundus -- Multimodal segmentation -- Ophthalmology -- Segmentation -- Optic nerve head -- Internal limiting membrane -- Graph-based segmentation -- Gradient vector flow
Diagnostic imaging -- Periodicals
Imaging systems in medicine -- Periodicals
Diagnosis, Radioscopic -- Data processing -- Periodicals
Diagnostic Imaging -- Periodicals
Imagerie pour le diagnostic -- Périodiques
Diagnostic imaging
Periodicals
Electronic journals
Electronic journals
616.0754 - Journal URLs:
- http://www.journals.elsevier.com/computerized-medical-imaging-and-graphics/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.compmedimag.2016.06.007 ↗
- Languages:
- English
- ISSNs:
- 0895-6111
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.586000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2321.xml