Thermal comfort and energy consumption in cold environment with retrofitted Huotong (warm-barrel). (1st February 2017)
- Record Type:
- Journal Article
- Title:
- Thermal comfort and energy consumption in cold environment with retrofitted Huotong (warm-barrel). (1st February 2017)
- Main Title:
- Thermal comfort and energy consumption in cold environment with retrofitted Huotong (warm-barrel)
- Authors:
- He, Yingdong
Li, Nianping
Zhou, Linxuan
Wang, Kuan
Zhang, Wenjie - Abstract:
- Abstract: This study aims to investigate subjective comfort and energy consumption in cold environment with retrofitted Huotong (warm-barrel). A series of experiments was conducted in one experimental room in Hunan University, China in winter. 16 subjects were exposed to the environments at 9, 12, 15 and 18 °C with retrofitted Huotong. During each test, subjective responses and Huotong's energy consumption were recorded. The obtained results indicates that Huotong maintained overall and local comfort in cold environment. With it, 90% acceptable temperature range could be extended to 9 °C. Thermal sensation, comfort and acceptability improved within 15 min after subjects turning on Huotong, while their preference for warm environment was weaken. Moreover, the heating power required for maintaining comfort increased as temperature was lower. When air temperature dropped from 18 to 9 °C, the average heating power rose from 50.3 to 165.6 W for each person. In addition, based on Corrective Power (CP), a new index (Corrective Energy & Power, i.e. CEP) for evaluating performance of both comfort and energy consumption of personal comfort system (PCS) was proposed. This index makes it possible to compare different PCSs in terms of extending acceptable temperature range and energy-efficiency simultaneously. Highlights: A series of experiments was carried out to test the effects of Huotong. Huotong well maintained subjective comfort in cold environment. A new index was proposed forAbstract: This study aims to investigate subjective comfort and energy consumption in cold environment with retrofitted Huotong (warm-barrel). A series of experiments was conducted in one experimental room in Hunan University, China in winter. 16 subjects were exposed to the environments at 9, 12, 15 and 18 °C with retrofitted Huotong. During each test, subjective responses and Huotong's energy consumption were recorded. The obtained results indicates that Huotong maintained overall and local comfort in cold environment. With it, 90% acceptable temperature range could be extended to 9 °C. Thermal sensation, comfort and acceptability improved within 15 min after subjects turning on Huotong, while their preference for warm environment was weaken. Moreover, the heating power required for maintaining comfort increased as temperature was lower. When air temperature dropped from 18 to 9 °C, the average heating power rose from 50.3 to 165.6 W for each person. In addition, based on Corrective Power (CP), a new index (Corrective Energy & Power, i.e. CEP) for evaluating performance of both comfort and energy consumption of personal comfort system (PCS) was proposed. This index makes it possible to compare different PCSs in terms of extending acceptable temperature range and energy-efficiency simultaneously. Highlights: A series of experiments was carried out to test the effects of Huotong. Huotong well maintained subjective comfort in cold environment. A new index was proposed for evaluating comfort and energy consumption of PCS. … (more)
- Is Part Of:
- Building and environment. Volume 112(2017)
- Journal:
- Building and environment
- Issue:
- Volume 112(2017)
- Issue Display:
- Volume 112, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 112
- Issue:
- 2017
- Issue Sort Value:
- 2017-0112-2017-0000
- Page Start:
- 285
- Page End:
- 295
- Publication Date:
- 2017-02-01
- Subjects:
- Thermal comfort -- Energy consumption -- Huotong -- CEP index
Buildings -- Environmental engineering -- Periodicals
Building -- Research -- Periodicals
Constructions -- Technique de l'environnement -- Périodiques
Electronic journals
696 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03601323 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.buildenv.2016.11.044 ↗
- Languages:
- English
- ISSNs:
- 0360-1323
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2359.355000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 414.xml