Surgical management of driveline infections in patients with left ventricular assist devices. Issue 12 (20th October 2016)
- Record Type:
- Journal Article
- Title:
- Surgical management of driveline infections in patients with left ventricular assist devices. Issue 12 (20th October 2016)
- Main Title:
- Surgical management of driveline infections in patients with left ventricular assist devices
- Authors:
- Pieri, Marina
Scandroglio, Anna Mara
Müller, Marcus
Pergantis, Panagiotis
Kretzschmar, Alexandra
Kaufmann, Friedrich
Falk, Volkmar
Krabatsch, Thomas
Arlt, Georg
Potapov, Evgenij
Kukucka, Marian - Abstract:
- Abstract: BACKGROUND AND AIM OF THE STUDY: Driveline infections in patients with implantable left ventricular assist devices (VAD) carry increasing risk for pump infection, thromboembolic events, decreased quality of life, and increased hospitalization. We report our experience with a surgical technique for refractory driveline infections without mediastinitis consisting of translocation and wrapping of the driveline with greater omentum tissue. METHODS: We retrospectively reviewed data of VAD patients who underwent surgical treatment by translocation and wrapping with omentum for severe chronic driveline infection. RESULTS: Thirteen patients were treated between January 2010 and October 2015; 12 (92%) were male, and the mean age was 56 ± 14 years. Ten patients (77%) were managed with driveline sheathing with omentum and repositioning with a new exit site, and three (23%), suffering from driveline fistula, with driveline covering with omentum maintaining the previous exit site. Three episodes of postoperative bleeding (23%) required surgical revision. Twelve patients (92%) were discharged from the hospital and one (8%) died. Nine patients (69%) were free from infection at the time of discharge, and three (23%) had recurrence of infection within the first postoperative year. Only four patients (31%) required admission to the intensive care unit; overall median hospital stay was 23 days (range 7‐205 days). CONCLUSIONS: Driveline relocation with use of omentum is a feasible andAbstract: BACKGROUND AND AIM OF THE STUDY: Driveline infections in patients with implantable left ventricular assist devices (VAD) carry increasing risk for pump infection, thromboembolic events, decreased quality of life, and increased hospitalization. We report our experience with a surgical technique for refractory driveline infections without mediastinitis consisting of translocation and wrapping of the driveline with greater omentum tissue. METHODS: We retrospectively reviewed data of VAD patients who underwent surgical treatment by translocation and wrapping with omentum for severe chronic driveline infection. RESULTS: Thirteen patients were treated between January 2010 and October 2015; 12 (92%) were male, and the mean age was 56 ± 14 years. Ten patients (77%) were managed with driveline sheathing with omentum and repositioning with a new exit site, and three (23%), suffering from driveline fistula, with driveline covering with omentum maintaining the previous exit site. Three episodes of postoperative bleeding (23%) required surgical revision. Twelve patients (92%) were discharged from the hospital and one (8%) died. Nine patients (69%) were free from infection at the time of discharge, and three (23%) had recurrence of infection within the first postoperative year. Only four patients (31%) required admission to the intensive care unit; overall median hospital stay was 23 days (range 7‐205 days). CONCLUSIONS: Driveline relocation with use of omentum is a feasible and effective procedure in selected cases of chronic severe driveline infection. The risk for perioperative bleeding should be taken into consideration and carefully monitored. … (more)
- Is Part Of:
- Journal of cardiac surgery. Volume 31:Issue 12(2016)
- Journal:
- Journal of cardiac surgery
- Issue:
- Volume 31:Issue 12(2016)
- Issue Display:
- Volume 31, Issue 12 (2016)
- Year:
- 2016
- Volume:
- 31
- Issue:
- 12
- Issue Sort Value:
- 2016-0031-0012-0000
- Page Start:
- 765
- Page End:
- 771
- Publication Date:
- 2016-10-20
- Subjects:
- Heart -- Surgery -- Periodicals
617.412005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8191 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=jcs ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/jocs.12860 ↗
- Languages:
- English
- ISSNs:
- 0886-0440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.863500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1319.xml