Test–retest reliability of skeletal muscle oxygenation measurements during submaximal cycling exercise in patients with chronic heart failure. (3rd July 2015)
- Record Type:
- Journal Article
- Title:
- Test–retest reliability of skeletal muscle oxygenation measurements during submaximal cycling exercise in patients with chronic heart failure. (3rd July 2015)
- Main Title:
- Test–retest reliability of skeletal muscle oxygenation measurements during submaximal cycling exercise in patients with chronic heart failure
- Authors:
- Niemeijer, Victor M.
Spee, Ruud F.
Jansen, Jasper P.
Buskermolen, Antonetta B. C.
van Dijk, Thomas
Wijn, Pieter F. F.
Kemps, Hareld M. C. - Abstract:
- Summary: The potential purpose of near‐infrared spectroscopy (NIRS) as a clinical application in patients with chronic heart failure (CHF) is the identification of limitations in O2 delivery or utilization during exercise. The objective of this study was to evaluate absolute and relative test–retest reliability of skeletal muscle oxygenation measurements in patients with CHF. Thirty patients with systolic heart failure (left ventricular ejection fraction 31 ± 8%) performed 6‐min constant‐load cycling tests at 80% of the anaerobic threshold (AT) with tissue saturation index (TSI) measurement at the vastus lateralis. Tests were repeated after 10 ± 5 days to evaluate reliability. Absolute reliability was assessed with limits of agreement (LoA, expressed as bias ± random error) and coefficients of variation (CV) for absolute values (LoA range: 0·4 ± 6·2% to 0·6 ± 7·9%; CV range: 4·7–7·1%), amplitudes (LoA range −0·5 ± 5·8% to −0·7 ± 6·8%; CV range: 26·2–42·1%), onset and recovery kinetics (mean response times; LoA 0·4 ± 9·5 s, CV 23·5% and LoA −5·8 ± 50·8 s, CV 67·4% respectively) and overshoot characteristics (CV range 45·7–208·6%). Relative reliability was assessed with intraclass correlation coefficients for absolute values (range 0·74–0·90), amplitudes (range 0·85–0·92), onset and recovery kinetics (0·53 and 0·51, respectively) and overshoot characteristics (range 0·17–0·74). In conclusion, absolute reliability of absolute values and onset kinetics seems acceptable forSummary: The potential purpose of near‐infrared spectroscopy (NIRS) as a clinical application in patients with chronic heart failure (CHF) is the identification of limitations in O2 delivery or utilization during exercise. The objective of this study was to evaluate absolute and relative test–retest reliability of skeletal muscle oxygenation measurements in patients with CHF. Thirty patients with systolic heart failure (left ventricular ejection fraction 31 ± 8%) performed 6‐min constant‐load cycling tests at 80% of the anaerobic threshold (AT) with tissue saturation index (TSI) measurement at the vastus lateralis. Tests were repeated after 10 ± 5 days to evaluate reliability. Absolute reliability was assessed with limits of agreement (LoA, expressed as bias ± random error) and coefficients of variation (CV) for absolute values (LoA range: 0·4 ± 6·2% to 0·6 ± 7·9%; CV range: 4·7–7·1%), amplitudes (LoA range −0·5 ± 5·8% to −0·7 ± 6·8%; CV range: 26·2–42·1%), onset and recovery kinetics (mean response times; LoA 0·4 ± 9·5 s, CV 23·5% and LoA −5·8 ± 50·8 s, CV 67·4% respectively) and overshoot characteristics (CV range 45·7–208·6%). Relative reliability was assessed with intraclass correlation coefficients for absolute values (range 0·74–0·90), amplitudes (range 0·85–0·92), onset and recovery kinetics (0·53 and 0·51, respectively) and overshoot characteristics (range 0·17–0·74). In conclusion, absolute reliability of absolute values and onset kinetics seems acceptable for serial within‐subject comparison, and as such, for evaluation of treatment effects. Absolute reliability of amplitudes and recovery kinetics is considered unsatisfactory. Relative reliability of absolute values and amplitudes is sufficient for purposes of physiological distinction between patients with CHF. Despite lower relative reliability, kinetics may still be useful for clinical application. … (more)
- Is Part Of:
- Clinical physiology and functional imaging. Volume 37:Number 1(2017:Jan.)
- Journal:
- Clinical physiology and functional imaging
- Issue:
- Volume 37:Number 1(2017:Jan.)
- Issue Display:
- Volume 37, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 37
- Issue:
- 1
- Issue Sort Value:
- 2017-0037-0001-0000
- Page Start:
- 68
- Page End:
- 78
- Publication Date:
- 2015-07-03
- Subjects:
- heart failure -- intraclass correlation coefficient -- limits of agreement -- near‐infrared spectroscopy -- repeatability -- reproducibility
Physiology, Pathological -- Periodicals
Diagnostic imaging -- Periodicals
612 - Journal URLs:
- http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=cpf ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/cpf.12269 ↗
- Languages:
- English
- ISSNs:
- 1475-0961
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.333520
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1930.xml