Bench and initial preclinical results of a novel 8 mm diameter double opposed helical biodegradable stent. Issue 6 (29th July 2016)
- Record Type:
- Journal Article
- Title:
- Bench and initial preclinical results of a novel 8 mm diameter double opposed helical biodegradable stent. Issue 6 (29th July 2016)
- Main Title:
- Bench and initial preclinical results of a novel 8 mm diameter double opposed helical biodegradable stent
- Authors:
- Herbert, Carrie E.
Veeram Reddy, Surendranath
Welch, Tré R.
Wang, Jian
Richardson, James A.
Forbess, Joseph M.
Nugent, Alan W. - Abstract:
- Abstract : Background: Metallic endovascular stents are utilized off‐label in congenital heart disease. Biodegradable stents (BDS) offer potential advantages in a growing child. We have previously reported double opposed helical (DH) BDS up to 6 mm diameter (DH‐6). The objectives are to investigate the bench characteristics of larger 8 mm diameter BDS (DH‐8) manufactured with increasing strut thicknesses and the inflammatory profile in a porcine model. Methods: DH‐8 were manufactured with strut thicknesses 0.10, 0.12, and 0.18 mm and mechanical testing performed. Stents were deployed into the infrarenal descending aorta (DAO) of nine minipigs. At insertion (nonsurvival = 2), 1 week ( n = 2), 1 month ( n = 2), and 9 months ( n = 3) follow‐up angiography, intravascular ultrasound and histopathology were performed. Results: There was superior recoil and collapse pressure with increasing strut thickness, with 0.18 mm having 1.0% elastic recoil and collapse pressure 0.75 Atmospheres. There was good wall apposition at insertion with 5 BDS (4 DH‐8 and 1 DH‐6) but suboptimal in 4 as the minipigs infrarenal DAO were >8 mm (deployed at iliac bifurcation). Structural integrity was maintained in 8 BDS with 1 DH‐8 collapsed at 9 months, secondary to strut damage at insertion. No thrombosis was seen. There was mild inflammation and neointimal proliferation at 1 week and 1 month, but a moderate inflammatory response at 9 months. Conclusions: DH‐8 with increased strut thickness hadAbstract : Background: Metallic endovascular stents are utilized off‐label in congenital heart disease. Biodegradable stents (BDS) offer potential advantages in a growing child. We have previously reported double opposed helical (DH) BDS up to 6 mm diameter (DH‐6). The objectives are to investigate the bench characteristics of larger 8 mm diameter BDS (DH‐8) manufactured with increasing strut thicknesses and the inflammatory profile in a porcine model. Methods: DH‐8 were manufactured with strut thicknesses 0.10, 0.12, and 0.18 mm and mechanical testing performed. Stents were deployed into the infrarenal descending aorta (DAO) of nine minipigs. At insertion (nonsurvival = 2), 1 week ( n = 2), 1 month ( n = 2), and 9 months ( n = 3) follow‐up angiography, intravascular ultrasound and histopathology were performed. Results: There was superior recoil and collapse pressure with increasing strut thickness, with 0.18 mm having 1.0% elastic recoil and collapse pressure 0.75 Atmospheres. There was good wall apposition at insertion with 5 BDS (4 DH‐8 and 1 DH‐6) but suboptimal in 4 as the minipigs infrarenal DAO were >8 mm (deployed at iliac bifurcation). Structural integrity was maintained in 8 BDS with 1 DH‐8 collapsed at 9 months, secondary to strut damage at insertion. No thrombosis was seen. There was mild inflammation and neointimal proliferation at 1 week and 1 month, but a moderate inflammatory response at 9 months. Conclusions: DH‐8 with increased strut thickness had acceptable mechanical properties at the cost of an increased inflammatory response. Miniaturization to improve delivery and further investigation on the long‐term inflammatory profile of thicker struts, including through degradation, is needed. © 2016 Wiley Periodicals, Inc. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 88:Issue 6(2016)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 88:Issue 6(2016)
- Issue Display:
- Volume 88, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 88
- Issue:
- 6
- Issue Sort Value:
- 2016-0088-0006-0000
- Page Start:
- 902
- Page End:
- 911
- Publication Date:
- 2016-07-29
- Subjects:
- BIOD -- bioabsorbable devices/polymers -- SDES -- stent design/structure/coatings -- SBIO -- stent -- bioabsorbable
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.26647 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2310.xml