Application of Taguchi method in optimising thermal comfort and cognitive performance during direct load control events. (January 2017)
- Record Type:
- Journal Article
- Title:
- Application of Taguchi method in optimising thermal comfort and cognitive performance during direct load control events. (January 2017)
- Main Title:
- Application of Taguchi method in optimising thermal comfort and cognitive performance during direct load control events
- Authors:
- Zhang, Fan
de Dear, Richard - Abstract:
- Abstract: Direct load control (DLC) is a demand response strategy that allows a utility or an aggregator to cycle specific appliances of their customers on and off or implement thermostat setback during peak demand periods. In the present research, a methodology is proposed to optimise DLC air-conditioning algorithms in order to achieve optimum and robust thermal comfort and cognitive performance outcome for commercial building occupants using Taguchi method. Human subject experiments were carried out simulating DLC events with four control factors in a university lecture theatre. Results reveal that off cycle fraction and adapting temperature are the two most important control factors that affect both the variability and mean response of building occupants' thermal sensation; off cycle fraction is the only significant control factor that affects the robustness of occupants' cognitive performance while none of the four control factors has any significant impact on the mean performance scores. DLC algorithms with off cycle fraction not higher than 50% and adapting temperature lower than occupants' neutral temperature are recommended to achieve optimum and robust thermal comfort and cognitive performance outcome. Cycling period and building envelope thermal performance do not have any significant impact. DLC air-conditioning strategies can be widely implemented in commercial buildings with various thermal performance conditions as long as the off cycle fraction and adaptingAbstract: Direct load control (DLC) is a demand response strategy that allows a utility or an aggregator to cycle specific appliances of their customers on and off or implement thermostat setback during peak demand periods. In the present research, a methodology is proposed to optimise DLC air-conditioning algorithms in order to achieve optimum and robust thermal comfort and cognitive performance outcome for commercial building occupants using Taguchi method. Human subject experiments were carried out simulating DLC events with four control factors in a university lecture theatre. Results reveal that off cycle fraction and adapting temperature are the two most important control factors that affect both the variability and mean response of building occupants' thermal sensation; off cycle fraction is the only significant control factor that affects the robustness of occupants' cognitive performance while none of the four control factors has any significant impact on the mean performance scores. DLC algorithms with off cycle fraction not higher than 50% and adapting temperature lower than occupants' neutral temperature are recommended to achieve optimum and robust thermal comfort and cognitive performance outcome. Cycling period and building envelope thermal performance do not have any significant impact. DLC air-conditioning strategies can be widely implemented in commercial buildings with various thermal performance conditions as long as the off cycle fraction and adapting temperature are optimised. Highlights: A methodology is proposed to optimise thermal comfort and cognitive performance during DLC events. DLC algorithms with off cycle fraction not higher than 50% and adapting temperature lower than neutral are recommended. Either shorter or longer cycling period can be adopted. Building envelope thermal performance condition does not affect thermal comfort or cognitive performance. … (more)
- Is Part Of:
- Building and environment. Volume 111(2017)
- Journal:
- Building and environment
- Issue:
- Volume 111(2017)
- Issue Display:
- Volume 111, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 111
- Issue:
- 2017
- Issue Sort Value:
- 2017-0111-2017-0000
- Page Start:
- 160
- Page End:
- 168
- Publication Date:
- 2017-01
- Subjects:
- Direct load control (DLC) -- Air-conditioning -- Taguchi method -- Thermal sensation -- Cognitive performance
Buildings -- Environmental engineering -- Periodicals
Building -- Research -- Periodicals
Constructions -- Technique de l'environnement -- Périodiques
Electronic journals
696 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03601323 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.buildenv.2016.11.012 ↗
- Languages:
- English
- ISSNs:
- 0360-1323
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2359.355000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12.xml