Virus removal of new and aged UF membranes at full-scale in a wastewater reclamation plant. Issue 6 (10th October 2016)
- Record Type:
- Journal Article
- Title:
- Virus removal of new and aged UF membranes at full-scale in a wastewater reclamation plant. Issue 6 (10th October 2016)
- Main Title:
- Virus removal of new and aged UF membranes at full-scale in a wastewater reclamation plant
- Authors:
- Reeve, Petra
Regel, Rudi
Dreyfus, Jennifer
Monis, Paul
Lau, Melody
King, Brendon
van den Akker, Ben - Abstract:
- Abstract : We examined the consequence of long-term membrane ageing on the virus rejection performance of full-scale ultrafiltration membranes to better understand health risks associated with membrane use in wastewater reuse schemes. Abstract : Ultrafiltration (UF) membrane technology is widely used in water recycling schemes as a physical barrier for the removal of human pathogens. Assessing the consequence of long-term operation (membrane ageing) as well operational extremes on pathogen removal performance is crucial for assessing health risks of human exposure to recycled water. In this study, challenge testing with MS2 bacteriophage (MS2) was undertaken to validate the integrity of full-scale UF membranes used for virus removal in a wastewater recycling plant (WRP). Validation was performed on new (6 months old) and aged (6 years old) membrane units. The impact of a hazardous event—in the form of a short-lived, high turbidity spike—was also assessed since this event affected the hydraulic throughput of exposed membrane units. Validation of the new membranes demonstrated a mean virus log removal value (LRV) of 3.0 log10 (SD = 0.6), with 5th and 95th percentile values ranging between 2.3 and 3.9 log10 units. Re-validation of the membranes exposed to the hazardous event as well as those that were aged demonstrated that the virus LRV was comparable and had reduced by 1.0 log10 units, measuring 2.0 log10 (SD = 0.2), however the LRV performance was more stable, where the 5thAbstract : We examined the consequence of long-term membrane ageing on the virus rejection performance of full-scale ultrafiltration membranes to better understand health risks associated with membrane use in wastewater reuse schemes. Abstract : Ultrafiltration (UF) membrane technology is widely used in water recycling schemes as a physical barrier for the removal of human pathogens. Assessing the consequence of long-term operation (membrane ageing) as well operational extremes on pathogen removal performance is crucial for assessing health risks of human exposure to recycled water. In this study, challenge testing with MS2 bacteriophage (MS2) was undertaken to validate the integrity of full-scale UF membranes used for virus removal in a wastewater recycling plant (WRP). Validation was performed on new (6 months old) and aged (6 years old) membrane units. The impact of a hazardous event—in the form of a short-lived, high turbidity spike—was also assessed since this event affected the hydraulic throughput of exposed membrane units. Validation of the new membranes demonstrated a mean virus log removal value (LRV) of 3.0 log10 (SD = 0.6), with 5th and 95th percentile values ranging between 2.3 and 3.9 log10 units. Re-validation of the membranes exposed to the hazardous event as well as those that were aged demonstrated that the virus LRV was comparable and had reduced by 1.0 log10 units, measuring 2.0 log10 (SD = 0.2), however the LRV performance was more stable, where the 5th and 95th percentile values ranged between only 1.7 and 2.2 log10 units. Very little research has previously examined the consequence of membrane ageing or hazardous events on the LRV performance of full-scale UF systems, and thus the findings presented here will facilitate improvements in risk management, in the design of installations and in the operation of UF membrane systems. … (more)
- Is Part Of:
- Environmental science. Volume 2:Issue 6(2016)
- Journal:
- Environmental science
- Issue:
- Volume 2:Issue 6(2016)
- Issue Display:
- Volume 2, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 2
- Issue:
- 6
- Issue Sort Value:
- 2016-0002-0006-0000
- Page Start:
- 1014
- Page End:
- 1021
- Publication Date:
- 2016-10-10
- Subjects:
- Water-supply -- Periodicals
Water security -- Periodicals
Water resources development -- Periodicals
Water chemistry -- Periodicals
553.705 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/ew#!recentarticles&all ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c6ew00197a ↗
- Languages:
- English
- ISSNs:
- 2053-1400
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3791.599150
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 798.xml