X-ray emission spectroscopy: highly sensitive techniques for time-resolved probing of cerium reactivity under catalytic conditions. Issue 47 (21st November 2016)
- Record Type:
- Journal Article
- Title:
- X-ray emission spectroscopy: highly sensitive techniques for time-resolved probing of cerium reactivity under catalytic conditions. Issue 47 (21st November 2016)
- Main Title:
- X-ray emission spectroscopy: highly sensitive techniques for time-resolved probing of cerium reactivity under catalytic conditions
- Authors:
- Kopelent, R.
van Bokhoven, J. A.
Nachtegaal, M.
Szlachetko, J.
Safonova, O. V. - Abstract:
- Abstract : High sensitivity of X-ray emission spectroscopy based methods for in situ time-resolved quantification of Ce 3+ in ceria-based catalysts and related materials. Abstract : Oxygen storage materials such as ceria are used in many catalytic applications because they can reversibly bind and release oxygen. Tools are needed to observe and quantify this activity which involves a change in the cerium oxidation state and to understand the involvement of cerium in catalytic processes. To prove that cerium changes its oxidation state in the catalytic cycle the transient rates of Ce 3+ formation and decay should be compared to the overall reaction rate. For such mechanistic studies the time resolution is essential as the quantification of the Ce 3+ species should be faster than the reaction rate. However, it is challenging to follow the dynamic changes of the cerium oxidation state under reaction conditions, especially when the concentration of cerium atoms involved in the reaction cycle is low. In this paper, we evaluate the sensitivity of high-resolution X-ray emission-based methods for the in situ time-resolved quantification of small concentrations of Ce 3+ in ceria-based materials. We demonstrate that resonant X-ray emission spectroscopy (RXES) at optimal excitation energy is more sensitive than high energy resolution off-resonant spectroscopy (HEROS) and non-resonant X-ray emission spectroscopy (non-resonant XES) and that it can track the reactivity of less than 0.3% ofAbstract : High sensitivity of X-ray emission spectroscopy based methods for in situ time-resolved quantification of Ce 3+ in ceria-based catalysts and related materials. Abstract : Oxygen storage materials such as ceria are used in many catalytic applications because they can reversibly bind and release oxygen. Tools are needed to observe and quantify this activity which involves a change in the cerium oxidation state and to understand the involvement of cerium in catalytic processes. To prove that cerium changes its oxidation state in the catalytic cycle the transient rates of Ce 3+ formation and decay should be compared to the overall reaction rate. For such mechanistic studies the time resolution is essential as the quantification of the Ce 3+ species should be faster than the reaction rate. However, it is challenging to follow the dynamic changes of the cerium oxidation state under reaction conditions, especially when the concentration of cerium atoms involved in the reaction cycle is low. In this paper, we evaluate the sensitivity of high-resolution X-ray emission-based methods for the in situ time-resolved quantification of small concentrations of Ce 3+ in ceria-based materials. We demonstrate that resonant X-ray emission spectroscopy (RXES) at optimal excitation energy is more sensitive than high energy resolution off-resonant spectroscopy (HEROS) and non-resonant X-ray emission spectroscopy (non-resonant XES) and that it can track the reactivity of less than 0.3% of cerium atoms in a 1% Pt/CeO2 catalyst in a plug-flow reactor with sub-second time resolution. These results demonstrate that X-ray emission-based methods can be used as very sensitive tools and provide new insights into dynamic changes of the oxidation state in reducible oxides in a variety of applications. … (more)
- Is Part Of:
- Physical chemistry chemical physics. Volume 18:Issue 47(2016)
- Journal:
- Physical chemistry chemical physics
- Issue:
- Volume 18:Issue 47(2016)
- Issue Display:
- Volume 18, Issue 47 (2016)
- Year:
- 2016
- Volume:
- 18
- Issue:
- 47
- Issue Sort Value:
- 2016-0018-0047-0000
- Page Start:
- 32486
- Page End:
- 32493
- Publication Date:
- 2016-11-21
- Subjects:
- Chemistry, Physical and theoretical -- Periodicals
541.3 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/cp#!issueid=cp016040&type=current&issnprint=1463-9076 ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c6cp05830b ↗
- Languages:
- English
- ISSNs:
- 1463-9076
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.306000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2528.xml