Intra-Operative Cap Repositioning in Small Incision Lenticule Extraction (SMILE) for Enhanced Visual Recovery. (1st December 2016)
- Record Type:
- Journal Article
- Title:
- Intra-Operative Cap Repositioning in Small Incision Lenticule Extraction (SMILE) for Enhanced Visual Recovery. (1st December 2016)
- Main Title:
- Intra-Operative Cap Repositioning in Small Incision Lenticule Extraction (SMILE) for Enhanced Visual Recovery
- Authors:
- Shetty, Rohit
Shroff, Rushad
Kaweri, Luci
Jayadev, Chaitra
Kummelil, Mathew Kurian
Sinha Roy, Abhijit - Abstract:
- ABSTRACT: Purpose : To study the role of intra-operative cap repositioning in acute visual recovery after small incision lenticule extraction (SMILE). Materials and methods : Ninety-four eyes of 47 patients underwent the SMILE procedure for correction of myopic refractive error. Manifest refraction and visual quality parameters (optical quality analysis system) were evaluated before surgery. The Bowman's membrane was imaged using a handheld spectral domain optical coherence tomography device. All patients underwent an uneventful SMILE surgery by a single experienced surgeon. Intra-operative cap repositioning was done in the "right" eye of all patients (repositioned group) and the "left" eye of each patient served as controls (non-repositioned group). Visual acuity and optical quality were assessed 1 day and 1 week after surgery. Results : Bowman's membrane microdistortions were found in 21.3% of eyes in the repositioned group and 59.57% of the eyes in the non-repositioned group ( p = 0.003) on the first day after surgery. Comparison of optical quality parameters was carried out between eyes where repositioning was done and control eyes (with and without microdistortions). On the first day after surgery, the modulation transfer function (MTF) and Strehl's ratio (SR) were significantly better in the repositioned group when compared with the controls ( p = 0.002 and p = 0.003, respectively). Refractive error and lenticule thickness in eyes with microdistortions were similar ( pABSTRACT: Purpose : To study the role of intra-operative cap repositioning in acute visual recovery after small incision lenticule extraction (SMILE). Materials and methods : Ninety-four eyes of 47 patients underwent the SMILE procedure for correction of myopic refractive error. Manifest refraction and visual quality parameters (optical quality analysis system) were evaluated before surgery. The Bowman's membrane was imaged using a handheld spectral domain optical coherence tomography device. All patients underwent an uneventful SMILE surgery by a single experienced surgeon. Intra-operative cap repositioning was done in the "right" eye of all patients (repositioned group) and the "left" eye of each patient served as controls (non-repositioned group). Visual acuity and optical quality were assessed 1 day and 1 week after surgery. Results : Bowman's membrane microdistortions were found in 21.3% of eyes in the repositioned group and 59.57% of the eyes in the non-repositioned group ( p = 0.003) on the first day after surgery. Comparison of optical quality parameters was carried out between eyes where repositioning was done and control eyes (with and without microdistortions). On the first day after surgery, the modulation transfer function (MTF) and Strehl's ratio (SR) were significantly better in the repositioned group when compared with the controls ( p = 0.002 and p = 0.003, respectively). Refractive error and lenticule thickness in eyes with microdistortions were similar ( p > 0.05) between the two groups indicating other contributors to acute optical quality postoperatively. Conclusions : Although the refractive error before surgery determines the extent of microdistortions, intra-operative cap repositioning can reduce them, thereby expediting acute visual recovery after SMILE. … (more)
- Is Part Of:
- Current eye research. Volume 41:Number 12(2016:Dec.)
- Journal:
- Current eye research
- Issue:
- Volume 41:Number 12(2016:Dec.)
- Issue Display:
- Volume 41, Issue 12 (2016)
- Year:
- 2016
- Volume:
- 41
- Issue:
- 12
- Issue Sort Value:
- 2016-0041-0012-0000
- Page Start:
- 1532
- Page End:
- 1538
- Publication Date:
- 2016-12-01
- Subjects:
- Handheld spectral domain optical coherence tomography -- microdistortions -- repositioning -- small incision lenticule extraction (SMILE) -- visual quality
Ophthalmology -- Periodicals
Eye -- Diseases -- Periodicals
Ophthalmology -- Periodicals
573.88 - Journal URLs:
- http://informahealthcare.com/journal/cey ↗
http://www.tandfonline.com/toc/icey20/current ↗
http://informahealthcare.com ↗ - DOI:
- 10.3109/02713683.2016.1168848 ↗
- Languages:
- English
- ISSNs:
- 0271-3683
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3496.570000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2073.xml