Cardiac helical CT involving a low-radiation-dose protocol with a 100-kVp setting: Usefulness of hybrid iterative reconstruction and display preset optimization. Issue 46 (November 2016)
- Record Type:
- Journal Article
- Title:
- Cardiac helical CT involving a low-radiation-dose protocol with a 100-kVp setting: Usefulness of hybrid iterative reconstruction and display preset optimization. Issue 46 (November 2016)
- Main Title:
- Cardiac helical CT involving a low-radiation-dose protocol with a 100-kVp setting
- Authors:
- Iyama, Yuji
Nakaura, Takeshi
Yokoyama, Koichi
Kidoh, Masafumi
Yamashita, Yasuyuki - Editors:
- Roever., Leonardo
- Abstract:
- Abstract : Abstract: To compare the radiation dose and image quality of retrospective electrocardiogram (ECG)-gated cardiac computed tomography (CT) between a 100-kVp protocol, hybrid iterative reconstruction (HIR), and display preset optimization and the 120-kVp protocol. We prospectively enrolled 100 patients with tachycardia or atrial fibrillation scanned retrospective ECG-gated cardiac CT. We randomly assigned 50 patients to the 120-kVp protocol and 50 patients to the 100-kVp protocol. We compared effective doses (EDs) between the two protocols. The 120-kVp images were post-processed using filtered back projection (FBP). The 100-kVp images were post-processed using FBP (100-kVp protocol) and HIR (i-100-kVp protocol). We compared attenuation of the ascending aorta, signal-to-noise ratio (SNR), and image noise between the 120-kVp, 100-kVp, and i-100-kVp protocols. We performed qualitative image analysis for the 120-kVp and i-100-kVp protocols. ED of the 100-kVp protocol (4.4 ± 0.4 mSv) was 76% lower than that of the 120-kVp protocol (18.4 ± 0.6 mSv). Attenuations of the 100-kVp (549.1 ± 73.8 HU) and i-100-kVp (550.5 ± 73.7 HU) protocols were higher than that of the120-kVp protocol (437.3 ± 55.7 HU). Image noise of the 100-kVp (53.6 ± 18.5 HU) and i-100-kVp (30.9 ± 8.6 HU) protocols were higher than that of the120-kVp protocol (23.8 ± 5.7 HU). There was no significant difference in SNR and the result of qualitative image analysis between the 120-kVp and i-100-kVp protocols.Abstract : Abstract: To compare the radiation dose and image quality of retrospective electrocardiogram (ECG)-gated cardiac computed tomography (CT) between a 100-kVp protocol, hybrid iterative reconstruction (HIR), and display preset optimization and the 120-kVp protocol. We prospectively enrolled 100 patients with tachycardia or atrial fibrillation scanned retrospective ECG-gated cardiac CT. We randomly assigned 50 patients to the 120-kVp protocol and 50 patients to the 100-kVp protocol. We compared effective doses (EDs) between the two protocols. The 120-kVp images were post-processed using filtered back projection (FBP). The 100-kVp images were post-processed using FBP (100-kVp protocol) and HIR (i-100-kVp protocol). We compared attenuation of the ascending aorta, signal-to-noise ratio (SNR), and image noise between the 120-kVp, 100-kVp, and i-100-kVp protocols. We performed qualitative image analysis for the 120-kVp and i-100-kVp protocols. ED of the 100-kVp protocol (4.4 ± 0.4 mSv) was 76% lower than that of the 120-kVp protocol (18.4 ± 0.6 mSv). Attenuations of the 100-kVp (549.1 ± 73.8 HU) and i-100-kVp (550.5 ± 73.7 HU) protocols were higher than that of the120-kVp protocol (437.3 ± 55.7 HU). Image noise of the 100-kVp (53.6 ± 18.5 HU) and i-100-kVp (30.9 ± 8.6 HU) protocols were higher than that of the120-kVp protocol (23.8 ± 5.7 HU). There was no significant difference in SNR and the result of qualitative image analysis between the 120-kVp and i-100-kVp protocols. The 100-kVp protocol with HIR reduced the 76% radiation dose while preserving the image quality compared with the conventional 120-kVp protocol on retrospective ECG-gated cardiac CT. … (more)
- Is Part Of:
- Medicine. Volume 95:Issue 46(2016)
- Journal:
- Medicine
- Issue:
- Volume 95:Issue 46(2016)
- Issue Display:
- Volume 95, Issue 46 (2016)
- Year:
- 2016
- Volume:
- 95
- Issue:
- 46
- Issue Sort Value:
- 2016-0095-0046-0000
- Page Start:
- e5459
- Page End:
- Publication Date:
- 2016-11
- Subjects:
- cardiac CT -- display preset optimization -- hybrid iterative reconstruction -- low-voltage tube technique
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000005459 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 180.xml