In vivo skin dose measurement using MOSkin detectors in tangential breast radiotherapy. Issue 11 (November 2016)
- Record Type:
- Journal Article
- Title:
- In vivo skin dose measurement using MOSkin detectors in tangential breast radiotherapy. Issue 11 (November 2016)
- Main Title:
- In vivo skin dose measurement using MOSkin detectors in tangential breast radiotherapy
- Authors:
- Jong, W.L.
Ung, N.M.
Wong, J.H.D.
Ng, K.H.
Wan Ishak, W.Z.
Abdul Malik, R.
Phua, V.C.E.
Cutajar, D.L.
Metcalfe, P.E.
Rosenfeld, A.B.
Ho, G.F. - Abstract:
- Highlights: Patients' skin dose during tangential breast radiotherapy have been determined. EBT2 film and PBC overestimated the skin dose. The skin dose is approached and exceeded the dose toxicity level for skin erythema. The use of suitable metrological device is necessary to determine actual skin dose. Abstract: The purpose of this study is to measure patient skin dose in tangential breast radiotherapy. Treatment planning dose calculation algorithm such as Pencil Beam Convolution (PBC) and in vivo dosimetry techniques such as radiochromic film can be used to accurately monitor radiation doses at tissue depths, but they are inaccurate for skin dose measurement. A MOSFET-based (MO Skin ) detector was used to measure skin dose in this study. Tangential breast radiotherapies ("bolus" and "no bolus") were simulated on an anthropomorphic phantom and the skin doses were measured. Skin doses were also measured in 13 patients undergoing each of the techniques. In the patient study, the EBT2 measurements and PBC calculation tended to over-estimate the skin dose compared with the MO Skin detector (p < 0.05) in the "no bolus radiotherapy". No significant differences were observed in the "bolus radiotherapy" (p > 0.05). The results from patients were similar to that of the phantom study. This shows that the EBT2 measurement and PBC calculation, while able to predict accurate doses at tissue depths, are inaccurate in predicting doses at build-up regions. The clinical application of theHighlights: Patients' skin dose during tangential breast radiotherapy have been determined. EBT2 film and PBC overestimated the skin dose. The skin dose is approached and exceeded the dose toxicity level for skin erythema. The use of suitable metrological device is necessary to determine actual skin dose. Abstract: The purpose of this study is to measure patient skin dose in tangential breast radiotherapy. Treatment planning dose calculation algorithm such as Pencil Beam Convolution (PBC) and in vivo dosimetry techniques such as radiochromic film can be used to accurately monitor radiation doses at tissue depths, but they are inaccurate for skin dose measurement. A MOSFET-based (MO Skin ) detector was used to measure skin dose in this study. Tangential breast radiotherapies ("bolus" and "no bolus") were simulated on an anthropomorphic phantom and the skin doses were measured. Skin doses were also measured in 13 patients undergoing each of the techniques. In the patient study, the EBT2 measurements and PBC calculation tended to over-estimate the skin dose compared with the MO Skin detector (p < 0.05) in the "no bolus radiotherapy". No significant differences were observed in the "bolus radiotherapy" (p > 0.05). The results from patients were similar to that of the phantom study. This shows that the EBT2 measurement and PBC calculation, while able to predict accurate doses at tissue depths, are inaccurate in predicting doses at build-up regions. The clinical application of the MO Skin detectors showed that the average total skin doses received by patients were 1662 ± 129 cGy (medial) and 1893 ± 199 cGy (lateral) during "no bolus radiotherapy". The average total skin doses were 4030 ± 72 cGy (medial) and 4004 ± 91 cGy (lateral) for "bolus radiotherapy". In some cases, patient skin doses were shown to exceed the dose toxicity level for skin erythema. Hence, a suitable device for in vivo dosimetry is necessary to accurately determine skin dose. … (more)
- Is Part Of:
- Physica medica. Volume 32:Issue 11(2016)
- Journal:
- Physica medica
- Issue:
- Volume 32:Issue 11(2016)
- Issue Display:
- Volume 32, Issue 11 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 11
- Issue Sort Value:
- 2016-0032-0011-0000
- Page Start:
- 1466
- Page End:
- 1474
- Publication Date:
- 2016-11
- Subjects:
- MOSFET -- Breast conserving radiotherapy -- Chest wall irradiation -- Surface dose -- Superficial dose -- In vivo dosimetry
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.10.022 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1692.xml