Axillary ultrasound and Fine-Needle Aspiration Cytology in the preoperative staging of axillary node metastasis in breast cancer patients. (December 2016)
- Record Type:
- Journal Article
- Title:
- Axillary ultrasound and Fine-Needle Aspiration Cytology in the preoperative staging of axillary node metastasis in breast cancer patients. (December 2016)
- Main Title:
- Axillary ultrasound and Fine-Needle Aspiration Cytology in the preoperative staging of axillary node metastasis in breast cancer patients
- Authors:
- Gipponi, Marco
Fregatti, Piero
Garlaschi, Alessandro
Murelli, Federica
Margarino, Cecilia
Depaoli, Francesca
Baccini, Paola
Gallo, Maurizio
Friedman, Daniele - Abstract:
- Abstract: Objective: A prospective observational clinical study was undertaken to assess the accuracy of preoperative Axillary Ultrasound (AUS) plus Fine-Needle Aspiration Cytology (FNAC) as well as and its clinical utility, that is the capacity of the information supplied by the test to guide the clinical decision-making. Materials and methods: from January 2013 to August 2015, 400 female patients with pT1-3 cN0 operable breast cancer underwent AUS with FNAC at the Breast Unit of the " IRCCS San Martino-IST " in Genoa (Italy). Results: 127 out of 400 patients (31.7%) had axillary lymph node metastases; in 69 out of 127 node-positive patients (54.3%) AUS detected at least one abnormal lymph node, and in 56 out of 127 patients (44.1%) the abnormal sonographic pattern of the lymph node was coupled with a positive FNAC finding. No false-positive finding by both AUS-alone or combined AUS/FNAC was observed. AUS-alone had sensitivity of 54.3% (69/127), specificity of 100% (273/273), PPV of 100% (69/69), NPV of 82.5% (273/331), and accuracy of 85.5% (342/400). Combined AUS/FNAC had sensitivity of 44.1% (56/127), specificity of 100% (273/273), PPV of 100% (56/56), NPV of 79.4% (273/344), and accuracy of 82.2% (329/400). Conclusions: AUS-alone or combined AUS/FNAC had a high accuracy rate coupled with a more than satisfactory efficiency due to their low costs and easy access for the preoperative staging of the axilla. Notably, AUS-alone might be suggested for the preoperative stagingAbstract: Objective: A prospective observational clinical study was undertaken to assess the accuracy of preoperative Axillary Ultrasound (AUS) plus Fine-Needle Aspiration Cytology (FNAC) as well as and its clinical utility, that is the capacity of the information supplied by the test to guide the clinical decision-making. Materials and methods: from January 2013 to August 2015, 400 female patients with pT1-3 cN0 operable breast cancer underwent AUS with FNAC at the Breast Unit of the " IRCCS San Martino-IST " in Genoa (Italy). Results: 127 out of 400 patients (31.7%) had axillary lymph node metastases; in 69 out of 127 node-positive patients (54.3%) AUS detected at least one abnormal lymph node, and in 56 out of 127 patients (44.1%) the abnormal sonographic pattern of the lymph node was coupled with a positive FNAC finding. No false-positive finding by both AUS-alone or combined AUS/FNAC was observed. AUS-alone had sensitivity of 54.3% (69/127), specificity of 100% (273/273), PPV of 100% (69/69), NPV of 82.5% (273/331), and accuracy of 85.5% (342/400). Combined AUS/FNAC had sensitivity of 44.1% (56/127), specificity of 100% (273/273), PPV of 100% (56/56), NPV of 79.4% (273/344), and accuracy of 82.2% (329/400). Conclusions: AUS-alone or combined AUS/FNAC had a high accuracy rate coupled with a more than satisfactory efficiency due to their low costs and easy access for the preoperative staging of the axilla. Notably, AUS-alone might be suggested for the preoperative staging of patients with early stage breast cancer because FNAC did not increased the specificity but reduced the sensitivity of the technique. Patients with negative findings might undergo either SLNB or close observation while waiting for the definitive results of ongoing SOUND randomized clinical trial. Highlights: The adoption of very strict echographic criteria and the availability of a dedicated Radiologist achieved a 100% specificity and PPV. FNAC findings reduced the sensitivity as compared to AUS-alone, although with a high positive detection-rate of 82%. Sensitivity of AUS/FNAC was lower in T1 versus T2 tumors due to greater tumor-burden within the lymph-nodes in larger tumors. Fourteen percent of patients who tested AUS/FNAC+ could be immediately triaged to ALND thus avoiding SLNB. False-negative AUS findings should have no detrimental effect as for the regional and systemic therapeutic planning. … (more)
- Is Part Of:
- Breast. Volume 30(2016)
- Journal:
- Breast
- Issue:
- Volume 30(2016)
- Issue Display:
- Volume 30, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 30
- Issue:
- 2016
- Issue Sort Value:
- 2016-0030-2016-0000
- Page Start:
- 146
- Page End:
- 150
- Publication Date:
- 2016-12
- Subjects:
- Breast cancer -- Sentinel lymph node -- Staging
Breast -- Diseases -- Periodicals
Breast -- Tumors -- Periodicals
Breast -- Periodicals
Electronic journals
Periodicals
616 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09609776 ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0960-9776;screen=info;ECOIP ↗
http://www.harcourt-international.com/journals/brst/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/09609776 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/09609776 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.breast.2016.09.009 ↗
- Languages:
- English
- ISSNs:
- 0960-9776
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2277.492700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1287.xml