Test–retest reliability of rapid whole body and compartmental fat volume quantification on a widebore 3T MR system in normal‐weight, overweight, and obese subjects. Issue 6 (1st June 2016)
- Record Type:
- Journal Article
- Title:
- Test–retest reliability of rapid whole body and compartmental fat volume quantification on a widebore 3T MR system in normal‐weight, overweight, and obese subjects. Issue 6 (1st June 2016)
- Main Title:
- Test–retest reliability of rapid whole body and compartmental fat volume quantification on a widebore 3T MR system in normal‐weight, overweight, and obese subjects
- Authors:
- Newman, David
Kelly‐Morland, Christian
Leinhard, Olof Dahlqvist
Kasmai, Bahman
Greenwood, Richard
Malcolm, Paul N.
Romu, Thobias
Borga, Magnus
Toms, Andoni P. - Abstract:
- Abstract : Purpose: To measure the test–retest reliability of rapid (<15 min) whole body and visceral fat volume quantification in normal and obese subjects on a widebore 3T MR system and compare it with conventional manual segmentation. Materials and Methods: Thirty participants (body mass index [BMI] 20.1–48.6 kg/m 2 ) underwent two whole‐body magnetic resonance imaging (MRI) examinations on a widebore 3T machine using a 2‐point Dixon technique. Phase sensitive reconstruction and intensity inhomogeneity correction produced quantitative datasets of total adipose tissue (TAT), abdominal subcutaneous adipose tissue (ASAT), and visceral adipose tissue (VAT). The quantification was performed automatically using nonrigid atlas‐based segmentation and compared with manual segmentation (SliceOmatic). Results: The mean TAT was 31.74 L with a coefficient of variation (CV) of 0.79% and a coefficient of repeatability (CR) of 0.49 L. The ASAT was 7.92 L with a CV of 2.98% and a CR of 0.46 L. There was no significant difference in the semiautomated and manually segmented VAT ( P = 0.73) but there were differences in the reliability of the two techniques. The mean semiautomated VAT was 2.56 L, CV 1.8%, and CR 0.09 L compared to the mean manually segmented VAT of 3.12 L, where the CV was 6.3% and the CR was 0.39 L. Conclusion: Rapid semiautomated whole body and compartmental fat volume quantification can be derived from a widebore 3T system, for a range of body sizes including obeseAbstract : Purpose: To measure the test–retest reliability of rapid (<15 min) whole body and visceral fat volume quantification in normal and obese subjects on a widebore 3T MR system and compare it with conventional manual segmentation. Materials and Methods: Thirty participants (body mass index [BMI] 20.1–48.6 kg/m 2 ) underwent two whole‐body magnetic resonance imaging (MRI) examinations on a widebore 3T machine using a 2‐point Dixon technique. Phase sensitive reconstruction and intensity inhomogeneity correction produced quantitative datasets of total adipose tissue (TAT), abdominal subcutaneous adipose tissue (ASAT), and visceral adipose tissue (VAT). The quantification was performed automatically using nonrigid atlas‐based segmentation and compared with manual segmentation (SliceOmatic). Results: The mean TAT was 31.74 L with a coefficient of variation (CV) of 0.79% and a coefficient of repeatability (CR) of 0.49 L. The ASAT was 7.92 L with a CV of 2.98% and a CR of 0.46 L. There was no significant difference in the semiautomated and manually segmented VAT ( P = 0.73) but there were differences in the reliability of the two techniques. The mean semiautomated VAT was 2.56 L, CV 1.8%, and CR 0.09 L compared to the mean manually segmented VAT of 3.12 L, where the CV was 6.3% and the CR was 0.39 L. Conclusion: Rapid semiautomated whole body and compartmental fat volume quantification can be derived from a widebore 3T system, for a range of body sizes including obese patients, with "almost perfect" test–retest reliability. J. Magn. Reson. Imaging 2016;44:1464–1473. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 44:Issue 6(2016)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 44:Issue 6(2016)
- Issue Display:
- Volume 44, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 44
- Issue:
- 6
- Issue Sort Value:
- 2016-0044-0006-0000
- Page Start:
- 1464
- Page End:
- 1473
- Publication Date:
- 2016-06-01
- Subjects:
- semiautomated quantification -- manual segmentation -- MRI -- adipose -- visceral adipose -- reliability
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25326 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 816.xml