Preparation of the femoral bone cavity in cementless stems: broaching versus compaction: A 5-year randomized radiostereometric and dual X-ray absorptiometry study of 40 bilateral 1-stage operations. (1st November 2016)
- Record Type:
- Journal Article
- Title:
- Preparation of the femoral bone cavity in cementless stems: broaching versus compaction: A 5-year randomized radiostereometric and dual X-ray absorptiometry study of 40 bilateral 1-stage operations. (1st November 2016)
- Main Title:
- Preparation of the femoral bone cavity in cementless stems: broaching versus compaction
- Authors:
- Hjorth, Mette H
Stilling, Maiken
Søballe, Kjeld
Nielsen, Poul Torben
Christensen, Poul H
Kold, Søren - Abstract:
- Abstract : Background and purpose — Short-term experimental studies have confirmed that there is superior fixation of cementless implants inserted with compaction compared to broaching of the cancellous bone. Patients and methods — 1-stage, bilateral primary THA was performed in 28 patients between May 2001 and September 2007. The patients were randomized to femoral bone preparation with broaching on 1 side and compaction on the other side. 8 patients declined to attend the postoperative follow-up, leaving 20 patients (13 male) with a mean age of 58 (36–70) years for evaluation. The patients were followed with radiostereometric analysis (RSA) at baseline, at 6 and 12 weeks, and at 1, 2, and 5 years, and measurements of periprosthetic bone mineral density (BMD) at baseline and at 1, 2, and 5 years. The subjective part of the Harris hip score (HHS) and details of complications throughout the observation period were obtained at a mean interval of 6.3 (3.0–9.5) years after surgery. Results — Femoral stems in the compaction group had a higher degree of medio-lateral migration (0.21 mm, 95% CI: 0.03–0.40) than femoral stems in the broaching group at 5 years (p = 0.02). No other significant differences in translations or rotations were found between the 2 surgical techniques at 2 years (p > 0.4) and 5 years (p > 0.7) postoperatively. There were no individual stems with continuous migration. Periprosthetic BMD in the 7 Gruen zones was similar at 2 years and at 5 years.Abstract : Background and purpose — Short-term experimental studies have confirmed that there is superior fixation of cementless implants inserted with compaction compared to broaching of the cancellous bone. Patients and methods — 1-stage, bilateral primary THA was performed in 28 patients between May 2001 and September 2007. The patients were randomized to femoral bone preparation with broaching on 1 side and compaction on the other side. 8 patients declined to attend the postoperative follow-up, leaving 20 patients (13 male) with a mean age of 58 (36–70) years for evaluation. The patients were followed with radiostereometric analysis (RSA) at baseline, at 6 and 12 weeks, and at 1, 2, and 5 years, and measurements of periprosthetic bone mineral density (BMD) at baseline and at 1, 2, and 5 years. The subjective part of the Harris hip score (HHS) and details of complications throughout the observation period were obtained at a mean interval of 6.3 (3.0–9.5) years after surgery. Results — Femoral stems in the compaction group had a higher degree of medio-lateral migration (0.21 mm, 95% CI: 0.03–0.40) than femoral stems in the broaching group at 5 years (p = 0.02). No other significant differences in translations or rotations were found between the 2 surgical techniques at 2 years (p > 0.4) and 5 years (p > 0.7) postoperatively. There were no individual stems with continuous migration. Periprosthetic BMD in the 7 Gruen zones was similar at 2 years and at 5 years. Intraoperative femoral fractures occurred in 2 of 20 compacted hips, but there were none in the 20 broached hips. The HHS and dislocations were similar in the 2 groups at 6.3 (3.0–9.5) years after surgery. Interpretation — Bone compaction as a surgical technique with the Bi-Metric stem did not show the superior outcomes expected compared to conventional broaching. Furthermore, 2 periprosthetic fractures occurred using the compaction technique, so we cannot recommend compaction for insertion of the cementless Bi-Metric stem. … (more)
- Is Part Of:
- Acta orthopaedica. Volume 87:Number 6(2016)
- Journal:
- Acta orthopaedica
- Issue:
- Volume 87:Number 6(2016)
- Issue Display:
- Volume 87, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 87
- Issue:
- 6
- Issue Sort Value:
- 2016-0087-0006-0000
- Page Start:
- 575
- Page End:
- 582
- Publication Date:
- 2016-11-01
- Subjects:
- Orthopedics -- Periodicals
616.7005 - Journal URLs:
- http://informahealthcare.com/loi/ort ↗
http://www.tandfonline.com/toc/iort20/current ↗
https://actaorthop.org/actao/index ↗
http://www.tandfonline.com/ ↗
http://journalsonline.tandf.co.uk/app/home/journal.asp?wasp=65168817ff044fea9c5b577f1cfe2186&referrer=parent&backto=linkingpublicationresults, 1:113260, 1 ↗ - DOI:
- 10.1080/17453674.2016.1244958 ↗
- Languages:
- English
- ISSNs:
- 1745-3674
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0642.055000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2183.xml