Effective tube-in-tank PCM thermal storage for CSP applications, Part 2: Parametric assessment and impact of latent fraction. (1st December 2016)
- Record Type:
- Journal Article
- Title:
- Effective tube-in-tank PCM thermal storage for CSP applications, Part 2: Parametric assessment and impact of latent fraction. (1st December 2016)
- Main Title:
- Effective tube-in-tank PCM thermal storage for CSP applications, Part 2: Parametric assessment and impact of latent fraction
- Authors:
- Belusko, M.
Tay, N.H.S.
Liu, M.
Bruno, F. - Abstract:
- Highlights: PCM systems of high latent fraction should apply counterflow to the HTF. PCM systems of low latent fraction should apply parallel flow to the HTF. Heat transfer with counterflow tubes can have a reduced performance in some cases. Abstract: The tube-in-tank is a compact configuration well suited for PCM thermal storage systems. However limited research has investigated the impact of the boundary condition applied to the PCM achieved through differing tube arrangements. In Part 1, using CFD and considering the discharging condition for CSP applications, it was determined that when the heat transfer fluid flow was in parallel, poor extraction of latent energy occurs, whereas in a counterflow arrangement maximum latent energy is extracted. In Part 2, the impact of mass flow rate and PCM thermal conductivity on the extraction of latent energy for these tube arrangements was investigated. It was discovered that the counterflow arrangement can experience poorer heat transfer which can be avoided through design. Furthermore, little investigation has considered the impact of the effectiveness of heat transfer with PCM systems with increased amounts of sensible energy, typical for CSP applications. It was determined that for latent dominant storage systems, the counterflow tube arrangement should be applied, while for sensible dominant PCM storage systems, parallel flow should be considered.
- Is Part Of:
- Solar energy. Volume 139(2016)
- Journal:
- Solar energy
- Issue:
- Volume 139(2016)
- Issue Display:
- Volume 139, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 139
- Issue:
- 2016
- Issue Sort Value:
- 2016-0139-2016-0000
- Page Start:
- 744
- Page End:
- 756
- Publication Date:
- 2016-12-01
- Subjects:
- PCM thermal storage -- Effectiveness -- Sensible energy -- CSP
Solar energy -- Periodicals
Solar engines -- Periodicals
621.47 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0038092X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.solener.2015.09.034 ↗
- Languages:
- English
- ISSNs:
- 0038-092X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8327.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1080.xml