Venous access for hematopoietic progenitor cell collection: An international survey by the ASFA HPC donor subcommittee. Issue 6 (13th January 2016)
- Record Type:
- Journal Article
- Title:
- Venous access for hematopoietic progenitor cell collection: An international survey by the ASFA HPC donor subcommittee. Issue 6 (13th January 2016)
- Main Title:
- Venous access for hematopoietic progenitor cell collection: An international survey by the ASFA HPC donor subcommittee
- Authors:
- O'Leary, Mandy Flannery
Dunbar, Nancy M.
Kim, Haewon C.
Draper, Nicole L.
Linenberger, Michael
Schwartz, Joseph
Miller, Yvette
Murtaugh, Ally
West, F. Bernadette
Fernando, Leonor P.
Park, Yara A. - Abstract:
- Abstract : Purpose: Hematopoietic Progenitor Cell (HPC) collection by apheresis is performed in patients and donors to obtain HPCs for transplantation. Although studies have shown these procedures to be safe, successful collection cannot be performed without establishment of venous access. This project's objective was to ascertain the current practices of donor vein assessment and central venous catheter (CVC) usage.Methods : The American Society for Apheresis (ASFA) HPC subcommittee created an electronic survey about precollection vein assessment and line placement, care, and removal in autologous and allogeneic donors. It was distributed to >5, 000 possible participants, with one response analyzed per institution.Results : One hundred centers performing autologous and/or allogeneic procedures provided adequate responses for analysis. Donor vein assessment is most often performed by apheresis staff more than 1 week prior to collection. For patients with questionable access, the next step performed most often is secondary assessment for autologous procedures and CVC placement for allogeneic procedures. Most centers use interventional radiology to place CVCs in jugular veins on collection day with placement verification through electronic medical records. Verbal and written postinsertion CVC care instructions are routinely provided. The apheresis team frequently provides postinsertion CVC care for autologous patients. Heparin is used most often for CVC lock. When used, tissueAbstract : Purpose: Hematopoietic Progenitor Cell (HPC) collection by apheresis is performed in patients and donors to obtain HPCs for transplantation. Although studies have shown these procedures to be safe, successful collection cannot be performed without establishment of venous access. This project's objective was to ascertain the current practices of donor vein assessment and central venous catheter (CVC) usage.Methods : The American Society for Apheresis (ASFA) HPC subcommittee created an electronic survey about precollection vein assessment and line placement, care, and removal in autologous and allogeneic donors. It was distributed to >5, 000 possible participants, with one response analyzed per institution.Results : One hundred centers performing autologous and/or allogeneic procedures provided adequate responses for analysis. Donor vein assessment is most often performed by apheresis staff more than 1 week prior to collection. For patients with questionable access, the next step performed most often is secondary assessment for autologous procedures and CVC placement for allogeneic procedures. Most centers use interventional radiology to place CVCs in jugular veins on collection day with placement verification through electronic medical records. Verbal and written postinsertion CVC care instructions are routinely provided. The apheresis team frequently provides postinsertion CVC care for autologous patients. Heparin is used most often for CVC lock. When used, tissue plasminogen activator is usually instilled for up to 60 min.Conclusion : These data summarize the largest single survey of donor vein assessment at institutions performing HPC collections by apheresis. The variations identified in donor venous access practice warrant further investigation and consensus to establish best practices. J. Clin. Apheresis 31:529–534, 2016. © 2015 Wiley Periodicals, Inc. … (more)
- Is Part Of:
- Journal of clinical apheresis. Volume 31:Issue 6(2016)
- Journal:
- Journal of clinical apheresis
- Issue:
- Volume 31:Issue 6(2016)
- Issue Display:
- Volume 31, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 31
- Issue:
- 6
- Issue Sort Value:
- 2016-0031-0006-0000
- Page Start:
- 529
- Page End:
- 534
- Publication Date:
- 2016-01-13
- Subjects:
- Apheresis -- HPC -- stem cell collection -- Venous Access
Hemapheresis -- Periodicals
Blood -- Transfusion -- Periodicals
Blood -- Transfusion, Autologous -- Periodicals
Cell separation -- Periodicals
Leukapheresis -- Periodicals
Plasmapheresis -- Periodicals
615.39 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1098-1101 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jca.21445 ↗
- Languages:
- English
- ISSNs:
- 0733-2459
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.381500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 234.xml