An "all 5 mm ports" technique for laparoscopic day-case anti-reflux surgery: A consecutive case series of 205 patients. (November 2016)
- Record Type:
- Journal Article
- Title:
- An "all 5 mm ports" technique for laparoscopic day-case anti-reflux surgery: A consecutive case series of 205 patients. (November 2016)
- Main Title:
- An "all 5 mm ports" technique for laparoscopic day-case anti-reflux surgery: A consecutive case series of 205 patients
- Authors:
- Almond, L.M.
Charalampakis, V.
Mistry, P.
Hodson, J.
Lafaurie, G.
Matthews, J.
Singhal, R.
Super, P. - Abstract:
- Abstract: Introduction: Laparoscopic anti-reflux surgery is conventionally performed using two 10/12 mm ports. While laparoscopic procedures reduce post-operative pain, the use of larger ports invariably increases discomfort and affects cosmesis. We describe a new all 5 mm ports technique for laparoscopic anti-reflux surgery and present a review of our initial experience with this approach. Methods: All patients undergoing laparoscopic fundoplication over a 35 month period from February 2013 under the care of a single surgeon were included. A Lind laparoscopic fundoplication was performed using an all 5 mm port technique. Data was recorded prospectively on patient demographics, operating surgeon, surgical time, date of discharge, readmissions, complications, need for re-intervention, and reasons for admission. Results: Two hundred and five consecutive patients underwent laparoscopic fundoplication over the study period. The all 5 mm port technique was used in all cases, with conversion to a 12 mm port only once (0.49%). Median operating time was 52 min 185 (90.2%) patients were discharged as day cases. Increasing ASA grade and the presence of a hiatus hernia were associated with the need for overnight stay with admission required in 33% of patients with ASA 3, compared to 4% with ASA 1 (p = 0.001), and 29% of those with a hiatus hernia vs. 5% without (p < 0.001). No port-related complications occurred, and no patients developed recurrence of reflux symptoms. A single patientAbstract: Introduction: Laparoscopic anti-reflux surgery is conventionally performed using two 10/12 mm ports. While laparoscopic procedures reduce post-operative pain, the use of larger ports invariably increases discomfort and affects cosmesis. We describe a new all 5 mm ports technique for laparoscopic anti-reflux surgery and present a review of our initial experience with this approach. Methods: All patients undergoing laparoscopic fundoplication over a 35 month period from February 2013 under the care of a single surgeon were included. A Lind laparoscopic fundoplication was performed using an all 5 mm port technique. Data was recorded prospectively on patient demographics, operating surgeon, surgical time, date of discharge, readmissions, complications, need for re-intervention, and reasons for admission. Results: Two hundred and five consecutive patients underwent laparoscopic fundoplication over the study period. The all 5 mm port technique was used in all cases, with conversion to a 12 mm port only once (0.49%). Median operating time was 52 min 185 (90.2%) patients were discharged as day cases. Increasing ASA grade and the presence of a hiatus hernia were associated with the need for overnight stay with admission required in 33% of patients with ASA 3, compared to 4% with ASA 1 (p = 0.001), and 29% of those with a hiatus hernia vs. 5% without (p < 0.001). No port-related complications occurred, and no patients developed recurrence of reflux symptoms. A single patient required mesh repair of a large hiatus hernia. Conclusion: The all 5 mm ports approach to laparoscopic anti-reflux surgery is a safe, efficient, and cost-effective technique which facilitates same day discharge and minimises port related complications. National commissioning guidelines in the UK should target quality improvements in anti-reflux surgery based around day-case management. This would improve the service for these patients and culminate in cost savings for the NHS. Highlights: Two hundred and five patients underwent laparoscopic fundoplication using an all 5 mm port technique with conversion to a 12 mm port only once. In this unselected cohort, same day discharge was achieved in 89% of patients. Hiatal hernia repair using mesh was performed without the need to convert to larger ports. … (more)
- Is Part Of:
- International journal of surgery. Volume 35(2016)
- Journal:
- International journal of surgery
- Issue:
- Volume 35(2016)
- Issue Display:
- Volume 35, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 35
- Issue:
- 2016
- Issue Sort Value:
- 2016-0035-2016-0000
- Page Start:
- 214
- Page End:
- 217
- Publication Date:
- 2016-11
- Subjects:
- Anti-reflux surgery -- Laparoscopic fundoplication -- Gastro-oesophageal reflux disease -- Port-site complications
Surgery -- Periodicals
Surgical Procedures, Operative -- Periodicals
617.005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17439191 ↗
http://ees.elsevier.com/ijs/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijsu.2016.09.089 ↗
- Languages:
- English
- ISSNs:
- 1743-9191
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.685050
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 339.xml